Summary

  • Interop: libplctag, gologix, pylogix, etherip, eip-rs, node-ethernet-ip and EEIP.NET (ethernetip-interop v0.3.0, pinned by digest), via a capability-driven suite: every case a reference declares runs against the library's target (adapter, logix, logix-structures), and the library's originator runs against the reference targets (libplctag's ab_server, gologix). Documented stack limits are N/A with their reason. 173 pass, 0 fail, 129 N/A across eleven references (was 63).
  • Fixes found by the new peers:
    • Template attribute 4 sized for × 4 − 23 octets (Rockwell 1756-PM020), was − 21; Read Template at/past the end refused (pylogix looped).
    • Class 3 requests carry the connection's reply budget (server.Request.MaxReply); Logix replies keep within it (libplctag on a 504-octet connection got 1228).
    • Multiple Service Packet up to 1000 services (was 200; node-ethernet-ip sends ~220).
  • Docs: README comparison for all eleven stacks, interop references, coverage statuses and known deviations; RELEASE.md v0.3.0.

Test plan

  • make check (race, lint, coverage 98.6%, examples)
  • interop against the published, pinned v0.3.0 images: 173 pass, 0 fail, 129 N/A

🤖 Generated with Claude Code

boeboe and others added 4 commits October 26, 2026 18:32
… the connection size

Found by the new interop peers:
- Template attribute 4 is sized so that reading the definition takes
  words×4 − 23 octets (Logix 5000 Controllers Data Access, 1756-PM020);
  it was − 21, and pylogix, node-ethernet-ip and libplctag read 2 octets
  short. The client reads − 23. A Read Template starting at or past the
  end is refused (pylogix looped on an empty success).
- A request on a Class 3 connection carries the connection's reply
  budget (server.Request.MaxReply); Logix tag replies keep within it with
  a partial transfer (libplctag on a 504-octet connection got 1228).
- A Multiple Service Packet may carry up to 1000 services (was 200;
  node-ethernet-ip sends about 220 reads in one 4000-octet packet).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A capability-driven suite runs every case a reference declares, against
the library's target (adapter, logix and logix-structures fixtures) and,
for the references with a target (libplctag's ab_server, gologix), with
the library's originator; documented limits of a stack are recorded N/A
with their reason. The matrix covers eleven references: 173 pass, 0 fail,
129 N/A against the dev images of ethernetip-interop.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…3 pass, 129 N/A

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
@codecov

codecov Bot commented Oct 26, 2026

Copy link
Copy Markdown

Codecov Report

✅ All modified and coverable lines are covered by tests.

📢 Thoughts on this report? Let us know!

@boeboe
boeboe merged commit 640cd12 into main Oct 26, 2026
45 checks passed
@boeboe
boeboe deleted the feature/more-references branch October 26, 2026 19:28
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant