Pneumatic control circuits of a basic teaching kit, simulated from first principles with free software: a Modelica library of valves, tubes and cylinders (ISO 6358 flow, polytropic volumes, a cylinder with friction), eight lessons and three build-it-yourself exercises, three experiments with 48 runs, and an independent Python implementation that reproduces every run. Circuits are dragged, dropped, connected and run in OMEdit, OpenModelica's graphical editor, and animate after a simulation: pistons move, chambers and lines fill with pressure, valves show their active position, gauges read live (learn).
- Get it: green Code button above → Download ZIP, unzip.
- Install OpenModelica (free): Windows installer from https://openmodelica.org; macOS and Linux via Docker. Step by step: install.
- Open
modelica/PneumaticCircuits/package.moin OMEdit →Learn → Lessons → L01, press Simulate, then Diagram Window and Play: the circuit runs.
Then follow the eight lessons and three exercises: learn.
| A lesson running in OMEdit (speed control, returning) | An experiment (pressure-dependent stamping, on the workpiece) |
|---|---|
![]() |
![]() |
Blue is compressed air: chambers and lines fill with it, a valve's blue square is its active position, pistons move with the simulated position, gauges read the simulated pressure.
| Library | supply, tubes, 3/2 push-button, selector and roller valves, 5/2 selector, single- and double-pilot valves, AND and OR valves, one-way flow control, quick exhaust, pressure sequence valve, single- and double-acting cylinders, gauges |
| Learn | 8 lessons (direct and indirect control, OR, AND, speed control, quick exhaust, memory), 3 exercises with the parts placed but not connected, a sandbox |
| Experiments | the three below, 48 recorded runs |
| Proof | an independent Python implementation reproduces every run; 20 statements of the lessons checked against simulation; tests on Linux, Windows and macOS |
| Experiment | Circuit | What it shows |
|---|---|---|
| E1 two-hand press | two push buttons → two-pressure (AND) valve → pilot 5/2-way valve; one-way flow control (meter-out) and quick-exhaust valve | the AND logic and its limits; stroke times against the throttle; what the quick-exhaust valve gains; gauge pressures |
| E2 automatic reciprocation | selector switch, roller limit valves, double-pilot 5/2-way valve, two one-way flow controls | cycle time against the throttles; meter-in against meter-out under no load, an opposing load and an overrunning load |
| E3 pressure-dependent stamping | push button, double-pilot 5/2-way valve, meter-in, pressure sequence valve gated by a roller valve | force control by a pressure setting, and what fails without the gate, with meter-out, or with the button held |
- Return speed under meter-out is set by the throttle alone: v = C ρ0 R T0 / A, the conductance of the choked throttle over the piston area. The simulations match it within 1 % from 2.5 % to 30 % opening, at any supply from 3 to 6 bar (E1).
- The quick-exhaust valve shortens the extension from 0.123 s to 0.094 s (−24 %); the return is unchanged.
- A two-pressure valve is not a safety control: it has no time window (a button pressed 1.5 s late still starts the press), and releasing a button mid-stroke does not stop a 94 ms stroke.
- Meter-out holds the speed against the load (−3 % with 60 N against it); meter-in follows the load (−42 %) and lets a pulling load run away (+30 %) (E2).
- A pressure sequence valve sets the press force F = p_set A1 − F_c (within 0.6 N from 2 to 5 bar), provided the approach is metered in and the valve is enabled only near the work: the breakaway pressure peak and meter-out both defeat it (E3).
All are simulations; parameters without a datasheet are estimated, and their effect is quantified (sensitivity).
Python 3.10+ (pip install -r requirements.txt). The scripts use an installed OpenModelica, or
its Docker image if none is installed; --engine python needs neither.
scripts/omedit.sh # Linux/macOS: OMEdit from the Docker image
python3 scripts/play.py TwoHandPress opening=0.1 # one run with your settings, plotted (--list shows them)
python3 scripts/run_lessons.py # every lesson and variant, recorded; the lessons' statements checked
python3 scripts/run_experiments.py # all 48 runs, OpenModelica and the Python twin (about 5 min)
python3 scripts/make_figures.py # figures and circuit diagrams -> docs/img
python3 scripts/sensitivity.py # parameter sensitivity -> results/tables/sensitivity.csv
python3 -m pytest tests # tests (CI runs them on every push)| Install | Windows, macOS, Linux, step by step; troubleshooting |
| Learn | watch circuits run, the eight lessons with their recorded results, exercises, the sandbox |
| Software | the free and commercial tools compared, and why OpenModelica |
| Physics | every equation, and the results they predict in closed form |
| Components | the kit's parts, every parameter with its source and status |
| Experiments | hypothesis, procedure, results, verification and sensitivity for each experiment |
| For ENR312 students | which run serves which task of the course's pneumatics guideline |
modelica/PneumaticCircuits/ the Modelica library: components (Valves, Actuators, Sources, ...), Learn (lessons, exercises, sandbox), Experiments
python/pneusim/ the Python twin (model.py, circuits.py), scenarios, metrics, diagram drawing, OpenModelica runner
scripts/ play, run_lessons, run_experiments, make_figures, sensitivity, om.sh, omedit.sh
results/ data/ (every run, 5 ms; lessons/), tables/ (lessons, claims, experiments, cross-check, sensitivity), RUN_INFO.json
docs/ documentation and figures
tests/ pytest suite
Other apparatus of the same laboratory, each in its own repository: DC servo control (Rhino RMCS-2303), temperature control (Arduino), water-level control (Arduino).
MIT (LICENSE). Third-party software and cited sources: THIRD_PARTY.md.
Festo, Festo Didactic and FluidSIM are trademarks of Festo SE & Co. KG. This project is independent: it is not affiliated with, sponsored or endorsed by Festo. Festo part numbers and datasheets are cited only to identify where a parameter value comes from; no Festo text, drawing, software or datasheet is reproduced. The circuit symbols are drawn here after the ISO 1219-1 conventions.