25 changes: 25 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -2,6 +2,31 @@

All notable changes to the Sourceful Zap Home Assistant integration.

## [1.1.2] - 2026-11-04

### Added

- PV input sensors: MPPT 1 and 2 Voltage, Current and Power, from the `mppt`
array firmware 7.x sends. Current and power are positive while generating.
- L1-L3 Voltage, Current and Power from the inverter's AC output when the device
has no grid meter. Current and power are positive while supplying. A grid
meter on the same device keeps these sensors.

### Changed

- A device sensor is created when its first value arrives, without a reload.
An inverter with no grid meter no longer gets meter sensors that can never have
a value, because `/ders` lists a meter it never reads. A sensor that has had a
value stays, and shows unavailable when the value stops.
- Existing installs: sensors that never had a value stay in Home Assistant until
you delete them. They are marked as no longer provided.

### Documentation

- README and test docs rewritten. HACS now shows the corrected install steps.
- `hacs.json`: minimum Home Assistant version raised from 2024.1.0 to 2025.2.0,
the first version that can load this integration.

## [1.1.1] - 2026-11-02

### Fixed
Expand Down
10 changes: 4 additions & 6 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -51,25 +51,23 @@ The integration polls device data every 10 seconds by default. To change this, o

## Sensors

Each device on the gateway gets the sensors that match what it reports:
Each device on the gateway gets the sensors below that it has reported a value for. A sensor appears when its first value arrives, without a reload:

| Group | Sensors | Created for |
|-------|---------|-------------|
| Power | Power | Every device |
| Grid meter | Import, Export, Reactive Power, Grid Frequency, L1-L3 Voltage, Current and Power | Grid meters. P1 meters have no Grid Frequency. |
| Grid power | Grid Power | A grid meter on the same device as v2 solar or an inverter |
| Solar | Production, Temperature | Solar |
| Inverter | Inverter Power, Temperature, Grid Frequency | Inverters |
| Solar | Production, Temperature, MPPT 1 and 2 Voltage, Current and Power | Solar |
| Inverter | Inverter Power, Temperature, Grid Frequency. L1-L3 Voltage, Current and Power when the device has no grid meter. | Inverters |
| Battery | Battery (state of charge), Power, Voltage, Current, Temperature, Total Charge, Total Discharge, Upper Limit, Lower Limit, Available Charge, Available Discharge | Batteries |
| EV charger | EV Charger Power | EV chargers |
| Gateway | Gateway Uptime, Gateway Temperature, Gateway Memory Usage, Gateway Memory Free, Firmware Version, WiFi Status, WiFi SSID, Signal Strength | Every gateway |

Reactive power and battery available charge and discharge only have values when the device reports them.

Sign conventions:

- **Grid meter:** positive while importing.
- **Solar:** positive while generating.
- **Solar:** positive while generating, per MPPT input too.
- **Battery:** positive while charging, negative while discharging.
- **Inverter:** positive while the inverter is supplying.

Expand Down
83 changes: 71 additions & 12 deletions custom_components/sourceful_zap/datamodel.py
Original file line number Diff line number Diff line change
Expand Up @@ -17,6 +17,10 @@
* inverter AC power is negative while the inverter is supplying; ``inverter_power``
is negated so output reads positive, and it is not added to aggregate power
because solar and battery already account for that energy
* a PV input's current and power are negative while generating; the MPPT sensors
negate them so production reads positive, like the power sensor
* an inverter's phase current and power are negated like ``inverter_power``. They
fill the L1-L3 sensors only on a device with no grid meter
"""

from __future__ import annotations
Expand Down Expand Up @@ -63,6 +67,8 @@
"rated_power_W",
"rated_power",
)
# The Zap reads at most two PV inputs.
_MPPT_INPUTS = 2
_DER_RATED_KEYS: tuple[str, ...] = (
"rated_power",
"rated_power_W",
Expand Down Expand Up @@ -124,6 +130,13 @@ class ZapDeviceData(TypedDict, total=False):
# PV power limits
pv_upper_limit: float | None
pv_lower_limit: float | None
# PV inputs, v2 only. Current and power are positive while generating.
mppt1_voltage: float | None
mppt1_current: float | None
mppt1_power: float | None
mppt2_voltage: float | None
mppt2_current: float | None
mppt2_power: float | None
# v2-only measurements
inverter_power: float | None
ev_charger_power: float | None
Expand Down Expand Up @@ -260,12 +273,14 @@ def parse_device_data(
v2 = is_data_model_v2(device_data)
_LOGGER.debug("Parsing %s as data model %s", serial_number, "v2" if v2 else "v1")

meter_block = _block(device_data, "meter")
_apply_solar(data, _block(device_data, *PV_BLOCK_KEYS))
_apply_inverter(data, _block(device_data, "inverter"))
_apply_inverter(
data, _block(device_data, "inverter"), include_phases=meter_block is None
)
_apply_battery(data, _block(device_data, "battery"))
# v1 PV payloads ship an embedded meter that is not the grid meter.
# Ignore that object entirely. v2 meters next to solar are the grid meter.
meter_block = _block(device_data, "meter")
if meter_block is not None and (v2 or "pv" not in device_data):
_apply_meter(
data,
Expand Down Expand Up @@ -399,6 +414,29 @@ def _apply_solar(data: ZapDeviceData, block: dict[str, Any] | None) -> None:
if pv_lower is not None:
data["pv_lower_limit"] = pv_lower

_apply_mppt(data, block.get("mppt"))


def _apply_mppt(data: ZapDeviceData, inputs: Any) -> None:
"""Copy each PV input's DC values, with generation positive."""
if not isinstance(inputs, list):
return

values = cast(dict[str, Any], data)
for number, pv_input in enumerate(inputs[:_MPPT_INPUTS], start=1):
if not isinstance(pv_input, dict):
continue

voltage = _read_metric(pv_input, ("V_dc",), f"mppt{number}.V_dc", min_value=0)
if voltage is not None:
values[f"mppt{number}_voltage"] = voltage

for quantity, key in (("current", "A_dc"), ("power", "W_dc")):
reading = _read_metric(pv_input, (key,), f"mppt{number}.{key}")
if reading is not None:
# 0 - x keeps a 0 reading +0.
values[f"mppt{number}_{quantity}"] = 0.0 - reading


def _apply_battery(data: ZapDeviceData, block: dict[str, Any] | None) -> None:
if block is None:
Expand Down Expand Up @@ -488,7 +526,12 @@ def _apply_battery(data: ZapDeviceData, block: dict[str, Any] | None) -> None:
data["battery_lower_limit"] = batt_lower


def _apply_inverter(data: ZapDeviceData, block: dict[str, Any] | None) -> None:
def _apply_inverter(
data: ZapDeviceData,
block: dict[str, Any] | None,
*,
include_phases: bool,
) -> None:
if block is None:
return

Expand Down Expand Up @@ -517,6 +560,9 @@ def _apply_inverter(data: ZapDeviceData, block: dict[str, Any] | None) -> None:
if freq is not None:
data["grid_frequency"] = freq

if include_phases:
_apply_phases(data, block, "inverter", output_positive=True)


def _apply_meter(
data: ZapDeviceData,
Expand Down Expand Up @@ -559,7 +605,7 @@ def _apply_meter(
if grid_freq is not None:
data["grid_frequency"] = grid_freq

_apply_phases(data, block)
_apply_phases(data, block, "meter")

reactive = _read_metric(
block,
Expand All @@ -572,8 +618,19 @@ def _apply_meter(
_set_make(data, block, "meter_make")


def _apply_phases(data: ZapDeviceData, block: dict[str, Any]) -> None:
"""Copy L1/L2/L3 voltage, current, and power."""
def _apply_phases(
data: ZapDeviceData,
block: dict[str, Any],
source: str,
*,
output_positive: bool = False,
) -> None:
"""Copy L1/L2/L3 voltage, current, and power.

``output_positive`` negates current and power, for a block whose negative
values mean supplying.
"""
values = cast(dict[str, Any], data)
for phase, voltage_field, current_field, power_field in (
("l1", "l1_voltage", "l1_current", "l1_power"),
("l2", "l2_voltage", "l2_current", "l2_power"),
Expand All @@ -582,27 +639,29 @@ def _apply_phases(data: ZapDeviceData, block: dict[str, Any]) -> None:
voltage = _read_metric(
block,
_phase_keys(phase, "V"),
f"meter.{phase.upper()}_V",
f"{source}.{phase.upper()}_V",
min_value=0,
max_value=500,
)
values = cast(dict[str, Any], data)
if voltage is not None:
values[voltage_field] = voltage

current = _read_metric(
block,
_phase_keys(phase, "A"),
f"meter.{phase.upper()}_A",
f"{source}.{phase.upper()}_A",
min_value=-200,
max_value=200,
)
if current is not None:
values[current_field] = current
# 0 - x keeps a 0 reading +0.
values[current_field] = 0.0 - current if output_positive else current

power = _read_metric(block, _phase_keys(phase, "W"), f"meter.{phase.upper()}_W")
power = _read_metric(
block, _phase_keys(phase, "W"), f"{source}.{phase.upper()}_W"
)
if power is not None:
values[power_field] = power
values[power_field] = 0.0 - power if output_positive else power


def _apply_ev(data: ZapDeviceData, block: dict[str, Any] | None) -> None:
Expand Down
2 changes: 1 addition & 1 deletion custom_components/sourceful_zap/manifest.json
Original file line number Diff line number Diff line change
Expand Up @@ -9,7 +9,7 @@
"iot_class": "local_polling",
"issue_tracker": "https://github.com/srcfl/zap-home-assistant/issues",
"requirements": [],
"version": "1.1.1",
"version": "1.1.2",
"zeroconf": [
{
"type": "_http._tcp.local.",
Expand Down
Loading
Loading