You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
EV divergence check treats normal duty charging as an off-plan level #1244
The candidate compares measured EV progress with slot-average watts spread evenly through the interval. Duty dispatch intentionally charges at the allowed peak and stops after spending the energy budget.
Local reproduction: a 60 kWh EV, a one-hour action averaging 5.5 kW with an 11 kW peak. Normal delivery after 15 minutes exceeds the uniform estimate by more than two percentage points and causes a needless replan. The regression also covers an execution start halfway through the slot.
Expected: compare progress with the feasible earliest/latest placement of the planned pulse, while still detecting corrections outside that range. Fix and regression: #1240.
Activity