372 changes: 372 additions & 0 deletions doc/pmon/xcvrd_on_demand_refresh_hld.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,372 @@
# On-Demand Transceiver STATE_DB Refresh in xcvrd for CPO

High Level Design

Rev. 1.0

## Table of Contents

- [On-Demand Transceiver STATE\_DB Refresh in xcvrd for CPO](#on-demand-transceiver-state_db-refresh-in-xcvrd-for-cpo)
- [Table of Contents](#table-of-contents)
- [0 General](#0-general)
- [0.1 Revision](#01-revision)
- [0.2 Scope](#02-scope)
- [0.3 Definitions/Abbreviations](#03-definitionsabbreviations)
- [0.4 Overview](#04-overview)
- [0.5 Use case](#05-use-case)
- [1 Requirements](#1-requirements)
- [1.1 Architecture Design](#11-architecture-design)
- [1.2 Functional Requirements](#12-functional-requirements)
- [1.3 Configuration and Management Requirements](#13-configuration-and-management-requirements)
- [1.4 Scalability Requirements](#14-scalability-requirements)
- [1.5 Performance Requirements](#15-performance-requirements)
- [1.6 Warm/Fast boot Requirements](#16-warmfast-boot-requirements)
- [1.7 Multi ASIC Requirements](#17-multi-asic-requirements)
- [2 Design](#2-design)
- [2.1 Background](#21-background)
- [2.2 Motivation](#22-motivation)
- [2.3 Design details](#23-design-details)
- [2.3.1 APPL\_DB interface](#231-appl_db-interface)
- [Example](#example)
- [2.3.2 Flows diagram](#232-flows-diagram)
- [2.3.3 Event-ordering guard](#233-event-ordering-guard)
- [2.4 SAI API](#24-sai-api)
- [2.5 Platform API](#25-platform-api)
- [2.6 Lower Layer API](#26-lower-layer-api)
- [2.7 Counters](#27-counters)
- [2.8 Error handling](#28-error-handling)
- [2.9 Event logging](#29-event-logging)
- [2.10 Configuration and Mangement](#210-configuration-and-mangement)
- [2.10.1 Manifest (if the feature is an Application Extension)](#2101-manifest-if-the-feature-is-an-application-extension)
- [2.10.2 YANG Model](#2102-yang-model)
- [2.10.3 CLI](#2103-cli)
- [2.10.3.1 Command Structure](#21031-command-structure)
- [2.10.3.2 Usage Examples](#21032-usage-examples)
- [2.10.4 gNMI](#2104-gnmi)
- [2.11 DB Schema](#211-db-schema)
- [2.11.1 Data Sample](#2111-data-sample)
- [2.12 Memory Consumption](#212-memory-consumption)
- [2.13 Restrictions/Limitations](#213-restrictionslimitations)
- [Restrictions](#restrictions)
- [Limitations](#limitations)
- [3 Test Plan](#3-test-plan)
- [3.1 Quality Guarantee](#31-quality-guarantee)
- [3.2 Unit tests](#32-unit-tests)
- [4 Security](#4-security)
- [4.1 New API](#41-new-api)
- [4.2 New resources required](#42-new-resources-required)
- [4.3 Secrets](#43-secrets)
- [4.4 New 3rd party resources](#44-new-3rd-party-resources)
- [Reference table](#reference-table)

## 0 General

### 0.1 Revision

Table 1 Revision

| Rev | Date | Author | Change Description |
| --- | --- | --- | --- |
| 1.0 | 2026-07-28 | Natanel Gerbi | Base version |

### 0.2 Scope

This document defines an on-demand refresh mechanism in `xcvrd` that lets SONiC components to request a targeted re-read of selected transceiver STATE_DB tables for a port, without disrupting periodic polling.

### 0.3 Definitions/Abbreviations

| Term | Definition |
| --- | --- |
| xcvrd | Transceiver daemon in the pmon container |
| CPO | Co-Packaged Optics |
| OE | Optical Engine |
| ELSFP | External Laser Source |
| DOM | Digital Optical Monitoring |
| COR | Clear-on-Read field — cleared by hardware upon being read |
| CMIS | Common Management Interface Specification |
| APPL_DB | Redis application database |
| STATE_DB | Redis state database |
| Requester | Any local SONiC component that writes to the request table |
| Representative port | The first logical port mapped to the same physical port index |

### 0.4 Overview

`CpoDomInfoUpdateTask` collects telemetry from CPO OE's and ELS's and publishes the data under their corresponding logical ports in STATE_DB. Today, this collection runs periodically, so a component reacting to an event such as a fault indication must wait for the next polling cycle to obtain updated data.

### 0.5 Use case

A component that receives an asynchronous transceiver fault indication needs fresh diagnostic data immediately, without waiting for the next periodic poll.

## 1 Requirements

### 1.1 Architecture Design

### 1.2 Functional Requirements

1. A local SONiC component shall be able to request an immediate refresh of selected OE and ELS STATE_DB tables for specific port.
2. `CpoDomInfoUpdateTask` shall validate and process the request using existing `PortChangeObserver`, then report completion or failure through APPL_DB.
3. The requester shall use the representative logical port as the request key (the port with `subport=1` when the port is split, or `subport=0`/unset when it is not). A non-representative logical port, or an invalid port, shall be rejected with `ERROR:INVALID_PORT`.

### 1.3 Configuration and Management Requirements

### 1.4 Scalability Requirements

### 1.5 Performance Requirements

### 1.6 Warm/Fast boot Requirements

### 1.7 Multi ASIC Requirements

## 2 Design

### 2.1 Background

`CpoDomInfoUpdateTask` is the `xcvrd` worker that collects diagnostics for CPO vmodules, alongside `DomInfoUpdateTask` which handles pluggable transceivers.
On a periodic cycle it reads the sensors, status and fault flags of each OE and ELSFP, and publishes them in the OE and ELS `TRANSCEIVER_*` tables under the logical ports that use each device.

In each of these STATE_DB entries (for example `TRANSCEIVER_STATUS|Ethernet0`), there is a field called `last_update_time` that records when that entry was last written. The time is in UTC, formatted `%a %b %d %H:%M:%S %Y`, for example `Mon Jul 27 14:19:04 2026`.

In order to easily follow the Clear-on-Read (COR) fields, Each `*_FLAG` STATE_DB table also has three companion tables that `xcvrd` maintains whenever a flag value changes:

- `*_FLAG_SET_TIME` - record the time the flag last went from `0` to `1` or `never`
- `*_FLAG_CLEAR_TIME` - record the time it last went from `1` to `0` or `never`
- `*_FLAG_CHANGE_COUNT` - count the number of transitions.

### 2.2 Motivation

This feature is mainly for Clear-on-Read (COR) fields, and its purpose is to keep `CpoDomInfoUpdateTask` their only reader. A COR field is cleared by the hardware the moment it is read, so only the first reader sees the value. If a component reads the device itself, it competes with the task for that one value: whoever reads first gets the value, and the other finds the field already cleared. Asking the task to refresh, instead of reading the device, keeps a single reader and avoids that race.

Another motivation is to be able to update the tables right away, instead of waiting for the periodic cycle to finish.

### 2.3 Design details

#### 2.3.1 APPL_DB interface

The feature adds two APPL_DB tables. Both are keyed by the representative logical port, so a requester writes, watches and reads on one key.

**Table: `REFRESH_COUNTERS_ON_DEMAND` (APPL_DB)** — written by the requester

| Field | Type | Required | Description |
| --- | --- | --- | --- |
| (key) | string | yes | Representative logical port owned by `CpoDomInfoUpdateTask`, e.g. `Ethernet0`. Any other port is rejected. |
| `tables` | string | yes | Comma-separated list of STATE_DB table names to refresh. |
| `requested_timestamp` | string | yes | UTC time of the triggering event, used by the event-ordering guard (#2.3.3) and echoed in the done row for correlation. |
| `force` | string | no | `true` to bypass the event-ordering guard and force a hardware read. Defaults to `false`. |

**Table: `REFRESH_COUNTERS_ON_DEMAND_DONE` (APPL_DB)** — written by `CpoDomInfoUpdateTask`

| Field | Type | Required | Description |
| --- | --- | --- | --- |
| (key) | string | yes | Same logical port name used as the request key |
| `status` | string | yes | `OK`, `PARTIAL`, or `ERROR:<reason>` (#2.8) |
| `completed_timestamp` | string | yes | UTC time the refresh completed |
| `requested_timestamp` | string | yes | The correlated event time from the request |

`tables` may name any of the STATE_DB tables owned by `CpoDomInfoUpdateTask`:

| Device | Table | Data |
| --- | --- | --- |
| OE | `TRANSCEIVER_DOM_SENSOR` | Module and lane sensor values |
| OE | `TRANSCEIVER_DOM_FLAG` | Module and lane DOM flags |
| OE | `TRANSCEIVER_STATUS` | Module and lane status |
| OE | `TRANSCEIVER_STATUS_FLAG` | Module and lane status flags |
| ELS | `TRANSCEIVER_ELS_DOM_SENSOR` | Module and lane sensor values |
| ELS | `TRANSCEIVER_ELS_DOM_FLAG` | Module and lane DOM flags |
| ELS | `TRANSCEIVER_ELS_STATUS` | Module and lane status |
| ELS | `TRANSCEIVER_ELS_STATUS_FLAG` | Module and lane status flags |

Refreshing a `*_FLAG` table also updates its `*_FLAG_CHANGE_COUNT`, `*_FLAG_SET_TIME`, and `*_FLAG_CLEAR_TIME` companion tables, which `xcvrd` writes as a side effect of the flag writer whenever a value differs from the one already in STATE_DB.

##### Example

a component request refresh on `Ethernet0`

```text
APPL_DB REFRESH_COUNTERS_ON_DEMAND:Ethernet0
tables = TRANSCEIVER_DOM_FLAG,TRANSCEIVER_STATUS_FLAG,TRANSCEIVER_ELS_DOM_FLAG,TRANSCEIVER_ELS_STATUS_FLAG
requested_timestamp = Mon Jul 27 14:19:04 2026
force = false
```

and `CpoDomInfoUpdateTask` answers on the same port:

```text
APPL_DB REFRESH_COUNTERS_ON_DEMAND_DONE:Ethernet0
status = OK
completed_timestamp = Mon Jul 27 14:19:05 2026
requested_timestamp = Mon Jul 27 14:19:04 2026
```

#### 2.3.2 Flows diagram

A refresh starts at the requester and ends with the requester reading STATE_DB:

1. The requester writes a request row to `REFRESH_COUNTERS_ON_DEMAND`, keyed by the representative port, naming the tables it needs and the time of the event that triggered it, and then subscribed to `REFRESH_COUNTERS_ON_DEMAND_DONE`.
2. `PortChangeObserver` delivers the write to `CpoDomInfoUpdateTask`, which checks that it owns the port, queues the request, and deletes the request row now that it has been consumed.
3. The task reads the requested data from the OE or ELSFP and writes it to STATE_DB, skipping any table whose entry is already newer than the event.
4. The task writes a done row to `REFRESH_COUNTERS_ON_DEMAND_DONE` on the same port, reporting the outcome.
5. The requester picks up the done row from `REFRESH_COUNTERS_ON_DEMAND_DONE` whose `requested_timestamp` matches the one it sent, and reads the refreshed STATE_DB tables.

```mermaid
sequenceDiagram
autonumber
participant R as Requester
participant ARQ as APPL_DB(REFRESH_COUNTERS_ON_DEMAND)
participant DOM as CpoDomInfoUpdateTask
participant DEV as OE / ELSFP
participant ST as STATE_DB transceiver tables
participant ADN as APPL_DB(REFRESH_COUNTERS_ON_DEMAND_DONE)

rect rgba(128, 128, 128, 0.12)
Note over ARQ,DOM: Initialization
DOM->>ARQ: subscribe via PortChangeObserver
end

Note over R,ADN: On-demand refresh
R->>ARQ: write request row (representative port, tables, requested_timestamp, force)
R->>ADN: subscribe
ARQ-->>DOM: request event
DOM->>ARQ: delete request row after consumed
alt last_update_time older than requested_timestamp, or force
DOM->>DEV: read shared and banked values at their device scope
DEV-->>DOM: requested values
DOM->>ST: publish requested table data
else already captured since the event
Note over DOM: skip hardware read because STATE_DB is fresh
end
DOM->>ADN: write done row (status, completed_timestamp, requested_timestamp)
ADN-->>R: done event, matched by requested_timestamp
R->>ST: read refreshed values using the request port
```

#### 2.3.3 Event-ordering guard

A refresh may arrive for a table that periodic polling has just read. Reading the device again is wasted work, and for a clear-on-read field it would consume a flag that STATE_DB already reports.

So for each table named in `tables`, the task compares the request against the `last_update_time` field of that table's row for the requested port:

- `requested_timestamp` < `last_update_time`: the row already covers the event, so the read is skipped.
- `requested_timestamp` >=`last_update_time`: the device is read and the row is republished.

When `force=true` is set, the device is read anyway, regardless of the comparison.

### 2.4 SAI API

No SAI change.

### 2.5 Platform API

No new platform API is introduced. The design uses the existing port mapping and OE/ELSFP sharing information required by `CpoDomInfoUpdateTask`.

### 2.6 Lower Layer API

### 2.7 Counters

### 2.8 Error handling

`CpoDomInfoUpdateTask` reports the outcome in the `status` field of `REFRESH_COUNTERS_ON_DEMAND_DONE` and logs the details. The requester matches the response by `requested_timestamp`.

| `status` | Meaning |
| --- | --- |
| `OK` | Every requested table was refreshed, or safely skipped by the event-ordering guard |
| `PARTIAL` | At least one requested table was unknown and skipped; the remaining tables succeeded |
| `ERROR:<reason>` | The request could not be serviced; no refreshed data is guaranteed |

Defined reasons:

| Reason | Cause |
| --- | --- |
| `MALFORMED_REQUEST` | A required field is missing, `requested_timestamp` cannot be parsed, or no requested table is supported |
| `INVALID_PORT` | The key is not a representative logical port owned by `CpoDomInfoUpdateTask` |
| `DEVICE_ABSENT` | The OE or ELSFP is not present |
| `READ_FAILED` | A refresh of a supported table failed |

### 2.9 Event logging

### 2.10 Configuration and Mangement

#### 2.10.1 Manifest (if the feature is an Application Extension)

#### 2.10.2 YANG Model

#### 2.10.3 CLI

##### 2.10.3.1 Command Structure

##### 2.10.3.2 Usage Examples

#### 2.10.4 gNMI

### 2.11 DB Schema

This feature adds the two APPL_DB tables described in #2.3.1, and refreshes the OE and ELS STATE_DB tables listed there. No existing schema is changed.


#### 2.11.1 Data Sample

A DOM flag row and its set-time companion, after `vccHAlarm` asserted during the refresh:

```text
STATE_DB TRANSCEIVER_DOM_FLAG|Ethernet0
tempHAlarm = False
vccHAlarm = True
last_update_time = Mon Jul 27 14:19:05 2026

STATE_DB TRANSCEIVER_DOM_FLAG_SET_TIME|Ethernet0
tempHAlarm = never
vccHAlarm = Mon Jul 27 14:19:05 2026
```

### 2.12 Memory Consumption

When `CpoDomInfoUpdateTask` is not started, no request memory is allocated.
APPL_DB rows remain until overwritten or deleted.

### 2.13 Restrictions/Limitations

#### Restrictions

1. Only ports owned by `CpoDomInfoUpdateTask` and the OE/ELS tables listed in #2.3.1 are supported.
2. `CpoDomInfoUpdateTask` must remain the only reader of the COR fields refreshed by this feature.
3. `requested_timestamp` must represent the triggering-event time.

#### Limitations

1. Concurrent requests for the same physical port may be coalesced; the earliest `requested_timestamp` is returned in the shared done row.
2. A refresh of a COR field consumes the latched value, so the flag value published to STATE_DB may return to `0` at the next periodic pass. The transition itself remains recorded in the `*_FLAG_CHANGE_COUNT`, `*_FLAG_SET_TIME`, and `*_FLAG_CLEAR_TIME` tables.

## 3 Test Plan

### 3.1 Quality Guarantee

TBD

### 3.2 Unit tests

- A valid request is queued. A request for a port not owned by `CpoDomInfoUpdateTask`, or for a non-representative port, returns `ERROR:INVALID_PORT` and is not queued.
- Multiple requests for the same physical port are combined into one refresh request.
- `CpoDomInfoUpdateTask` reads module-scoped values once per OE or ELSFP sharing group and banked values for the requested physical port.
- A hardware read occurs unless the table's `last_update_time` is newer than `requested_timestamp`, including when the two are equal. `force=true` always triggers a read.
- A successful refresh returns `OK`. A request mixing supported and unsupported tables refreshes the supported ones and returns `PARTIAL`. A missing device or a failed refresh returns the matching `ERROR:<reason>`.
- A refresh that observes a flag transition updates the `*_FLAG_CHANGE_COUNT`, `*_FLAG_SET_TIME`, and `*_FLAG_CLEAR_TIME` tables for the affected fields.
- Requests do not change regular `DomInfoUpdateTask` behavior.

## 4 Security

Not needed.

### 4.1 New API

### 4.2 New resources required

### 4.3 Secrets

### 4.4 New 3rd party resources

## Reference table

| Reference | Link |
| --- | --- |
| xcvrd CPO Support | <https://github.com/nexthop-ai/SONiC/blob/a4d4ae336a0726f79897c290a41001e489299d29/doc/pmon/xcvrd_cpo.md> |
| Port Mapping for CPO Platforms | <https://github.com/sonic-net/SONiC/blob/master/doc/platform/port_mapping_for_cpo.md> |
| CMIS specification | <https://www.oiforum.com/wp-content/uploads/OIF-CMIS-05.3.pdf> |