Summary

While testing the newly added support for the Colmi ring (R11), I found a bug where the app was not sending the command for automated HR recording, and on syncs the ring was only sending SpO2, HRV and temperature.

Related issues

Type of change

  • 🐛 Bug fix (non-breaking change that fixes an issue)
  • ✨ New feature (non-breaking change that adds functionality)
  • 📟 New / improved wearable support (BLE driver layer)
  • 🤖 Coach / LLM change (tools, prompts, orchestration)
  • 🎨 UI / DesignSystem change
  • 🧹 Refactor / chore (no behavior change)
  • 📝 Docs only
  • ⚠️ Breaking change (existing data, settings, or APIs change)

How was this tested?

  • Added / updated unit tests (PulseLoopTests)
  • Ran the test suite locally (⌘U in Xcode)
  • Tested on a physical device with a real ring — model: Colmi R11 (same hardware as R02)
  • Tested with demo data (-seedDemo YES, no hardware)
  • N/A (docs / non-code change)

Privacy & data

  • This change does not send health data off-device without explicit user action.
  • No secrets, API keys, or personal data are committed.
  • N/A

Screenshots / recordings

Checklist

  • My code follows the project's style (SwiftLint passes).
  • I ran the tests and they pass.
  • I updated docs / README where relevant.
  • I read the Contributing guide.

@saksham2001