Add CTS700 Compact P support (Ethernet Modbus TCP) including electrical supplement switch (20464) - #5
Closed
master3395 wants to merge 56 commits into
Closed
master3395 wants to merge 56 commits into
master3395 wants to merge 56 commits into
Conversation
Wire board_type selection, corrected Compact P registers, and README setup notes so CTS700 can be tested on the fork beside unchanged CTS602.
Mirror cyberpanel root README/Contributing/License navigation and document each CTS602 and CTS700 model under docs/.
Point install docs at fork master so CTS700 work does not require a separate branch.
Add board auto-detect with confirm, Nilan-only Lovelace examples, and Open Source Guides hygiene. Fix CTS602 issues 217/221/220/178/232 and Norwegian nb translations for other HA users.
Older CTS700 firmware uses registers under 10000. Keep 2018+ Compact P path unchanged; auto-detect probes both.
Document every nilan.no SKU with honest dump-gated status. Add capability profiles, Compact P2 CTS602 guide, GEO/CTS400 gates, and dump checklist.
Keep 2018+/legacy/CTS602 paths intact while adding CTS700_NORDIC hybrid parity, era docs, and modbus_yaml reference files.
Make 1.3.x history easy to browse on GitHub with per-version notes and an index.
Document Compact P Køl Polar/Nordic/Arctic XL CTS700 LC drawings, expand T7/T9 + YAML DHW climate, and prefer CTS700_NORDIC aliases for NCS-700 hybrids.
Fan 1-4 only, HVAC readback, drop unreliable DHW Off, Nilan sensor names.
Heat/cool stay as status action; 5432 is not a user mode setpoint.
Match HA YAML climate write_register for 4746/20460; verify readback.
Avoid YAML hub name clash, warn on dual Modbus, clean sw_version, smarter T8.
Entity ids currently get the boiler_room_nilan_* prefix regardless of the user's selected area or device name. Without suggested_area, HA derives the prefix from the device name the user actually configured.
Addresses review: device_name/type are user-configurable and identical units would still collide. Hub name derives from sanitized entry_id, unique per config entry and stable across reloads.
Offline Nilan no longer stalls HA boot (15s connect timeout). Incorporate Martsola hub-scoped unique_ids with registry migration. Co-authored-by: Mikko Martsola <mikko@martsola.com> Refs #1
Multi-unit unique_ids + drop hardcoded Boiler Room suggested_area. Thanks @Martsola.
Credit multi-unit PR #1 and startup-stall feedback in the fork contributor list and CONTRIBUTING pointer.
Document CTS602 (~2008–present), CTS700 map eras (2015/2018/2019), and note CTS602 HMI types share board era without inventing SKU years.
Add hw_type 11 to verified supported_devices, including compressor DHW setpoint so water heaters appear. Fix DE T5 condenser label. Co-authored-by: DUC750 <mirko@seipel-web.de>
GitHub About sidebar on this fork stays empty; surface commit authors via contrib.rocks and link CONTRIBUTORS.md.
…owers docs from repo
Serialize hub calls and keep last good sensor/number values on brief read failures so entities do not flip to unknown. Replace site-specific to-do notes with generic dual-path docs and probe matrix output.
Point contributors to nilan.no / en.nilan.dk instead of hosting copyrighted manufacturer PDFs in the repository.
Document Modbus hub lock / last-good sensor values and official manual download index; restore missing 1.3.13 row in changelog table.
HACS/git installs the tag; the GitHub Release URL is notes only.
Keep prior on/off when Modbus briefly fails, and log filter alarm transitions and failed reads for easier field diagnosis.
Compact P 2018 can toggle the DHW electrical supplement heater from Home Assistant; Nordic still refuses that write because 20464 is not in the hybrid map.
Owner
Author
|
Closing this PR without merging. This compare had base CTS700 Compact P work (including register 20464 as an electrical supplement switch) is already on
|
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary
Adds CTS700 Compact P support over Ethernet Modbus TCP on this fork, including register 20464 as a read/write electrical supplement switch.
Nordic must not get or expose that switch. CTS700 Compact P is the Ethernet model; keep it separate from Nordic serial/Modbus RTU.
Relates to issue veista#19.
Example device IP used in docs and tests: 192.168.1.50 only.
Test plan
This fork PR is for visibility of the CTS700/1.3.16 diff on master3395/veista-nilan. Upstream review remains veista#233