Add CTS700 Compact P support (Ethernet Modbus TCP) including electrical supplement switch (20464) - #5

Closed
master3395 wants to merge 56 commits into
upstream-masterfrom
master
Closed

master3395 wants to merge 56 commits into
upstream-masterfrom
master

Conversation

@master3395

Copy link
Copy Markdown
Owner

Summary

Adds CTS700 Compact P support over Ethernet Modbus TCP on this fork, including register 20464 as a read/write electrical supplement switch.

Nordic must not get or expose that switch. CTS700 Compact P is the Ethernet model; keep it separate from Nordic serial/Modbus RTU.

Relates to issue veista#19.

Example device IP used in docs and tests: 192.168.1.50 only.

Test plan

  • CTS700 Compact P: 20464 electrical supplement switch is readable and writable
  • Nordic: 20464 switch is not created and not shown
  • Ethernet Modbus TCP still connects using example IP 192.168.1.50 in local docs only
  • Existing Nordic and CTS602 paths still load

This fork PR is for visibility of the CTS700/1.3.16 diff on master3395/veista-nilan. Upstream review remains veista#233

master3395 and others added 30 commits August 4, 2026 22:22
Wire board_type selection, corrected Compact P registers, and README setup notes so CTS700 can be tested on the fork beside unchanged CTS602.
Mirror cyberpanel root README/Contributing/License navigation and document each CTS602 and CTS700 model under docs/.
Point install docs at fork master so CTS700 work does not require a separate branch.
Add board auto-detect with confirm, Nilan-only Lovelace examples, and Open Source Guides hygiene. Fix CTS602 issues 217/221/220/178/232 and Norwegian nb translations for other HA users.
Older CTS700 firmware uses registers under 10000.
Keep 2018+ Compact P path unchanged; auto-detect probes both.
Document every nilan.no SKU with honest dump-gated status. Add capability profiles, Compact P2 CTS602 guide, GEO/CTS400 gates, and dump checklist.
Keep 2018+/legacy/CTS602 paths intact while adding CTS700_NORDIC hybrid parity, era docs, and modbus_yaml reference files.
Make 1.3.x history easy to browse on GitHub with per-version notes and an index.
Document Compact P Køl Polar/Nordic/Arctic XL CTS700 LC drawings, expand T7/T9 + YAML DHW climate, and prefer CTS700_NORDIC aliases for NCS-700 hybrids.
Fan 1-4 only, HVAC readback, drop unreliable DHW Off, Nilan sensor names.
Heat/cool stay as status action; 5432 is not a user mode setpoint.
Match HA YAML climate write_register for 4746/20460; verify readback.
Avoid YAML hub name clash, warn on dual Modbus, clean sw_version, smarter T8.
Entity ids currently get the boiler_room_nilan_* prefix regardless of
the user's selected area or device name. Without suggested_area, HA
derives the prefix from the device name the user actually configured.
Addresses review: device_name/type are user-configurable and identical
units would still collide. Hub name derives from sanitized entry_id,
unique per config entry and stable across reloads.
Offline Nilan no longer stalls HA boot (15s connect timeout).
Incorporate Martsola hub-scoped unique_ids with registry migration.

Co-authored-by: Mikko Martsola <mikko@martsola.com>
Refs #1
Multi-unit unique_ids + drop hardcoded Boiler Room suggested_area. Thanks @Martsola.
Credit multi-unit PR #1 and startup-stall feedback in the fork
contributor list and CONTRIBUTING pointer.
1.3.11: non-blocking Modbus setup + hub-scoped unique_id migration. Thanks @mark007 and @Martsola.
Document CTS602 (~2008–present), CTS700 map eras (2015/2018/2019),
and note CTS602 HMI types share board era without inventing SKU years.
Add hw_type 11 to verified supported_devices, including compressor
DHW setpoint so water heaters appear. Fix DE T5 condenser label.

Co-authored-by: DUC750 <mirko@seipel-web.de>
GitHub About sidebar on this fork stays empty; surface commit
authors via contrib.rocks and link CONTRIBUTORS.md.
Martsola and others added 26 commits August 16, 2026 18:30
Serialize hub calls and keep last good sensor/number values on brief
read failures so entities do not flip to unknown. Replace site-specific
to-do notes with generic dual-path docs and probe matrix output.
Point contributors to nilan.no / en.nilan.dk instead of hosting
copyrighted manufacturer PDFs in the repository.
Document Modbus hub lock / last-good sensor values and official
manual download index; restore missing 1.3.13 row in changelog table.
HACS/git installs the tag; the GitHub Release URL is notes only.
Keep prior on/off when Modbus briefly fails, and log filter alarm
transitions and failed reads for easier field diagnosis.
Compact P 2018 can toggle the DHW electrical supplement heater from Home Assistant; Nordic still refuses that write because 20464 is not in the hybrid map.
@master3395

Copy link
Copy Markdown
Owner Author

Closing this PR without merging.

This compare had base upstream-master and head master. Merging it would only update the dummy upstream-master branch, not default master.

CTS700 Compact P work (including register 20464 as an electrical supplement switch) is already on master at fd7f128. master remains the target branch.

origin/fix/1.3.11-startup-unique-ids is fully contained in master. Extra origin branches will be removed so this fork keeps only master and dev.

@master3395 master3395 closed this Oct 4, 2026