An advanced Home Assistant integration for controlling electric infrared (IR) floor heating systems using a dual-sensor topology with Time Proportional & Integral (TPI) control algorithm.

Overview

This integration provides sophisticated control of electric floor heating systems by monitoring both room air temperature and floor surface temperature. It implements a "Safety-Comfort-Demand" hierarchy to protect flooring materials while maintaining occupant comfort.

The specific system under analysis involves a high-load resistive heating element managed by a dual-sensor topology. The governing logic satisfies a primary setpoint for ambient air temperature while strictly adhering to two hierarchical constraints: an absolute maximum floor temperature to prevent material degradation, and a differential maximum floor temperature relative to the room air to ensure physiological comfort.

Theoretical Background

The Operational Context

Electric underfloor heating systems, particularly those utilizing carbon film technology, operate on the principle of Joule heating. The control problem arises from the decoupling of the heat source (the floor) and the controlled variable (the room air temperature). In modern construction involving temperature-sensitive materials like engineered wood, laminate, or vinyl, unbounded operation poses a severe risk of warping, delamination, or discoloration. Furthermore, physiological studies indicate that floor surface temperatures exceeding 29°C (84°F) can cause discomfort.

Thermodynamics of the Heating Plant

The plant consists of the electric IR film, the floor assembly, and the enclosed air volume.

  • Rapid Generation: Carbon strips reach operating temperature within seconds.
  • Conductive Latency: The heat must traverse the flooring stack, introducing a transport delay (dead time) of 10 to 30 minutes.
  • Thermal Storage: The floor assembly acts as a thermal capacitor, smoothing rapid switching but introducing inertia.

Electromechanical Switching Constraints

The selection of the control algorithm is constrained by the actuation hardware, typically a mechanical relay.

  • Relay Physics: Switching a high-current load causes contact erosion due to arcing.
  • PWM Incompatibility: Standard high-frequency PWM would destroy a mechanical relay in days.
  • TPI Solution: Time Proportional & Integral (TPI) control, or "Slow PWM," adapts PID logic to a time window measured in minutes, ensuring relay longevity while providing precise control.

Relay Life Calculation

Standard mechanical relays have an electrical life of ~100,000 cycles at full load.

  • PWM (1 Hz): 86,400 cycles/day → Failure in ~1.2 days.
  • Standard Thermostat (6 CPH): ~26,000 cycles/year → Failure in ~3.8 years.
  • Optimized TPI (4 CPH): ~17,500 cycles/year → Service life > 5-10 years.

The Veto Architecture

The controller implements a "Veto Architecture" that serves as a high-priority safety layer. While the Dual-PID Min-Selector (described below) provides smooth, proactive temperature limiting, the Veto system acts as a hard Safety Gate. It possesses the authority to immediately block any heat request if floor temperature limits are exceeded, regardless of PID demand.

graph TD
    subgraph "Demand Generation"
        DualPID[Dual-PID Min-Selector] --> Demand[Requested Demand %]
    end

    subgraph "Safety Logic"
        Floor[Floor Temp] --> CheckLimit{">= Effective Limit?"}
        CheckLimit -- Yes --> SetVeto[Set VETO]
        CheckLimit -- "No (Safe)" --> CheckRelease{"Releasing Veto?"}
        
        CheckRelease -- "No (Steady State)" --> Safe[SAFE]
        CheckRelease -- "Yes (Was Vetoed)" --> Budget{"Budget Available?"}
        
        Budget -- "Yes (-1 Token)" --> ClearVeto[Clear VETO]
        Budget -- No --> KeepVeto["Keep VETO (Budget Exhausted)"]
        
        SetVeto --> VetoState[VETO ACTIVE]
        KeepVeto --> VetoState
        ClearVeto --> Safe
        Safe --> Gate{Safety Gate}
        VetoState --> Gate
    end

    Demand --> Gate
    Gate -- Vetoed --> Zero[0% Output]
    Gate -- Allowed --> TPI[TPI Logic]
    TPI --> Relay[Relay Control]
Loading

Unique Feature: Differential Limiting

Most commercial thermostats only enforce an absolute floor limit (e.g., 28°C). This integration uniquely implements a Differential Limit ($T_{floor} - T_{room} \le \Delta_{max}$), ensuring the floor never feels uncomfortably hot relative to the room, preventing thermal shock to materials and the "hot feet" phenomenon.

Defining the Constraints:

  • $T_{room}$: Current Air Temperature
  • $T_{floor}$: Current Floor Temperature
  • $L_{abs}$: Absolute Maximum Floor Temperature (e.g., 28°C)
  • $\Delta_{max}$: Maximum Differential (default: 5.0°C)

The Logic: The differential limit creates a floating ceiling for the floor temperature: $$Limit_{diff} = T_{room} + \Delta_{max}$$

The effective limit for the floor at any given moment is the stricter (lower) of the absolute limit and the differential limit: $$Limit_{effective} = \min(L_{abs}, \ T_{room} + \Delta_{max})$$

Operational Examples: Assuming $L_{abs} = 28^{\circ}$C and $\Delta_{max} = 8^{\circ}$C:

  1. Scenario A (Cold Room): $T_{room} = 15^{\circ}$C

    • $Limit_{effective} = \min(28, 15 + 8) = 23^{\circ}$C
    • Result: Floor is limited to 23°C to prevent thermal shock.
  2. Scenario B (Warm Room): $T_{room} = 22^{\circ}$C

    • $Limit_{effective} = \min(28, 22 + 8) = 30^{\circ}$C (capped to 28°C)
    • Result: Absolute limit takes over at 28°C.

Transition Cost: The Safety Budget

To prevent "chattering" (rapid on/off cycling) when the floor temperature hovers exactly at the limit, the system employs a Safety Budget (Token Bucket algorithm).

  • Mechanism: Toggling the relay limits is not free. Releasing a safety veto (allowing heating) consumes a "budget token".
  • Refill: Tokens regenerate slowly over time (e.g., 1 token every 15 minutes).
  • Priority: Engaging the veto (turning OFF for safety) is always allowed, even if it causes a budget deficit. However, turning back ON requires a positive budget.
  • Result: This creates a dynamic, time-based hysteresis that strictly limits the maximum frequency of safety-related switching events, protecting the relay even in edge cases.

Control Logic Pseudocode

// Simplified Control Logic
void loop() {
  // 1. Calculate Limits
  float effective_limit = min(MAX_FLOOR_ABS, room_temp + MAX_DIFF);

  // 2. Safety Veto
  bool safety_veto = false;
  if (floor_temp >= effective_limit) {
    safety_veto = true;
  } else if (floor_temp > (effective_limit - HYSTERESIS) && was_vetoed) {
    safety_veto = true; // Hysteresis
  }

  // 3. PID Demand
  float demand = calculate_pid(target - room_temp);
  if (safety_veto) demand = 0;

  // 4. TPI Actuation
  control_relay(demand);
}

Dual-PID Min-Selector Architecture

This integration implements an advanced Dual-PID "Select-Low" (Min-Selector) Architecture to maximize heating performance while respecting floor temperature limits.

How It Works

The system uses two independent PID controllers operating in parallel:

  1. Room Temperature PID: Calculates heating demand to reach the user's target temperature
  2. Floor Limiter PID: Calculates the maximum allowable heating demand based on the current floor temperature relative to the effective floor limit

The final demand is the minimum of these two values (hence "Select-Low"), ensuring that whichever constraint is tighter takes precedence.

Min-Selector Logic with Anti-Windup

graph LR
    subgraph "Inputs"
        RS["Room Sensors<br/>(1..N)"]
        FS["Floor Sensors<br/>(1..M)"]
        PS["Power Sensors<br/>(1..K)"]
    end

    subgraph "State Estimation"
       RS --> KF[Kalman Filter]
       FS --> KF
       PS --> KF
       KF --> Room_T[Fused Room Temp]
       KF --> Floor_T[Fused Floor Temp]
    end

    subgraph "Demand Calculation"
        Target_T["Target Temp"]
        Room_T -->|Error| Room_PID["Room PID<br/>Kp, Ki, Kd"]
        Target_T -->|Error| Room_PID
        Room_PID -->|Room Demand| Selector["Min-Selector"]

        Eff_Limit["Effective Floor Limit"]
        Floor_T -->|Error| Floor_PID["Floor PID<br/>Kp, Ki, Kd"]
        Eff_Limit -->|Error| Floor_PID
        Floor_PID -->|Floor Demand| Selector

        Selector -->|Final Demand| AW["Anti-Windup Check"]
    end

    subgraph "Anti-Windup"
        AW -->|Floor restricts Room?| Pause["Pause Room PID<br/>Integration"]
        AW -->|No restriction| Normal["Normal PID<br/>Operation"]
    end

    AW -->|Final Demand| TPI["TPI Controller"]
    TPI -->|Relay State| Relay["Mechanical Relay"]
Loading

Key Features of the Dual-PID Architecture:

  • Smooth Floor Limit Approach: The floor PID smoothly approaches the limit instead of hard cutoff, reducing temperature oscillation
  • Anti-Windup Coordination: When the floor limit restricts heating, the room PID's integral term is paused to prevent windup
  • Decoupled Tuning: Room and floor controllers can be tuned independently for optimal performance
  • Diagnostic Visibility: All internal states (both PID demands, integral errors, selected demand) are exposed via sensors for fine-tuning

Room Temperature PID

Controls heating demand to reach the user's target temperature.

  • Default Kp: 80.0 (aggressive proportional response)
  • Default Ki: 2.0 (medium integral action for steady-state accuracy)
  • Default Kd: 15.0 (significant damping for smooth response)

Floor Limiter PID

Controls the maximum heating demand based on floor temperature approaching the effective limit.

  • Default Kp: 20.0 (moderate proportional feedback)
  • Default Ki: 0.5 (gentle integral for smooth limit approach)
  • Default Kd: 10.0 (damping to prevent oscillation at the limit)

This soft-limit approach allows the floor temperature to smoothly approach the limit without hard cutoffs, improving thermal efficiency and reducing comfort disruptions.

MIMO & Kalman Filter Architecture

This system moves beyond simpler thermostats by treating the heating problem as a Multiple-Input, Multiple-Output (MIMO) system (strictly MISO in terms of actuation, but MIMO in terms of state estimation).

Sensor Fusion

graph LR
    subgraph "Inputs"
        R["Room Sensors (1..N)"]
        F["Floor Sensors (1..M)"]
        Power[Heater Power state]
    end

    subgraph "Kalman Filter"
        Predict["Prediction Step<br/>(Physics Model)"]
        Gate["Dynamic Gating<br/>(Drop invalid sensors)"]
        Update["Update Step<br/>(Correction)"]
    end

    subgraph "Fused State Output"
        TR[Fused Room Temp]
        TF[Fused Floor Temp]
        Rates[Rate of Change]
    end
    
    Power -- "Control Input (u)" --> Predict
    R -- "Measurements (z)" --> Gate
    F -- "Measurements (z)" --> Gate
    Gate --> Update
    Predict -->|Prior Estimate| Update
    Update --> TR
    Update --> TF
    Update --> Rates
Loading

A Fusion Kalman Filter is used to combine readings from multiple sensors into stable, accurate state estimates.

  1. Multiple Inputs: Accepts lists of $N$ floor sensors and $M$ room sensors.
  2. State Estimation Vector: Maintains a 4-dimensional state state: $$x = [T_{floor}, \dot{T}{floor}, T{room}, \dot{T}_{room}]^T$$ Tracking both temperature and its rate of change ($\dot{T}$) allows for faster reaction to trends.
  3. Active Prediction: The filter uses the known power state of the heater (ON/OFF) as a control input ($u$) to predict future temperatures using a basic Newtonian physical model. $$x_{k+1} = F x_k + B u_k$$
  4. Dynamic Gating: If a sensor fails or becomes unavailable (returns None), the filter dynamically reshapes its measurement matrix ($H$) to exclude that sensor, ensuring the system continues to operate robustly as long as at least one sensor remains.

This approach provides superior noise rejection compared to simple averaging and allows the system to "anticipate" temperature changes based on heater activity.

Key Features

MIMO Sensor Fusion (Kalman Filter)

  • Input: Fuses data from multiple room and floor sensors.
  • Process: Uses a Kalman Filter to reject noise and estimate true temperature states.
  • Prediction: Incorporates heater power state to predict temperature evolution (Newtonian kinematics).

Advanced Safety Limits

  • Absolute Maximum Floor Temperature: Protects flooring materials (default: 28°C).
  • Differential Maximum: Limits temperature difference between floor and room (default: 5.0°C).
  • Dynamic Limit Calculation: Effective floor limit adapts based on current room temperature.
  • Safety Budget: Token bucket algorithm prevents rapid relay cycling when hovering near safety limits.

TPI (Time Proportional & Integral) Algorithm

  • Relay Protection: Designed for mechanical relays.
  • Cycle Period: Configurable (default: 900 seconds).
  • Minimum Cycle Duration: Prevents excessive relay switching (default: 60 seconds).
  • PID Control: Precise temperature regulation (Kp=80.0, Ki=2.0, Kd=15.0).

Boost Mode

  • Temporarily relaxes the differential limit when the room is far from the target temperature.
  • Enables faster warm-up from cold conditions.
  • Prevents "control stalling" where floor temperature is capped too low to effectively heat the room.
  • Activation: When error ≥ boost_temp_diff (default 1.5°C).
  • Effect: Increases effective floor limit to allow higher heat output.

Configuration Parameters

Parameter Description Default
heater Switch entity controlling the heating relay Required
room_sensor Primary room temperature sensor (legacy) Required*
floor_sensor Primary floor temperature sensor (legacy) Required*
room_sensors List of room sensors for MIMO fusion []
floor_sensors List of floor sensors for MIMO fusion []
power_sensors List of power sensors for Kalman prediction []
max_floor_temp Absolute maximum floor temperature (°C) 28.0
max_floor_temp_diff Maximum floor-room differential (°C) 5.0
cycle_period TPI cycle duration (seconds) 900
min_cycle_duration Minimum on/off time (seconds) 60
boost_mode Enable boost mode for faster warm-up true
boost_temp_diff Temperature error to activate boost (°C) 1.5
pid_kp Room PID Proportional gain 80.0
pid_ki Room PID Integral gain 2.0
pid_kd Room PID Derivative gain 15.0
floor_pid_kp Floor Limiter PID Proportional gain 20.0
floor_pid_ki Floor Limiter PID Integral gain 0.5
floor_pid_kd Floor Limiter PID Derivative gain 10.0
safety_hysteresis Hysteresis for safety limit (°C) 0.25
maintain_comfort_limit Enforce differential limit even when setpoint met false
safety_budget_capacity Max tokens for safety switching budget 2.0
safety_budget_interval Seconds to regenerate one token 300

*Either singular *_sensor or plural *_sensors must be provided.

Diagnostic Sensors

The integration provides several diagnostic sensors to monitor internal state:

  • sensor.<name>_demand_percent: Final heating demand (0-100%, result of min-selector).
  • sensor.<name>_room_pid_demand: Room temperature PID demand (0-100%).
  • sensor.<name>_floor_pid_demand: Floor limiter PID demand (0-100%).
  • sensor.<name>_effective_floor_limit: Current dynamic floor temperature limit (°C).
  • sensor.<name>_room_integral_error: Room PID integral error term (°C·s).
  • sensor.<name>_floor_integral_error: Floor limiter PID integral error term (°C·s).
  • sensor.<name>_relay_toggle_count: Total number of relay switching events (for maintenance tracking).
  • sensor.<name>_fused_room_temperature: Kalman-fused room temperature estimate.
  • sensor.<name>_fused_floor_temperature: Kalman-fused floor temperature estimate.
  • binary_sensor.<name>_safety_veto_active: Whether safety limits are currently blocking heating.
  • binary_sensor.<name>_maintain_comfort_limit: Whether the comfort limit is actively maintained.

State Attributes

The climate entity exposes the following additional attributes:

  • room_temperature: Current fused room air temperature.
  • floor_temperature: Current fused floor surface temperature.
  • demand_percent: Calculated heating demand.
  • effective_floor_limit: Dynamically calculated floor temperature limit.
  • safety_veto_active: Whether safety limits are currently restricting heating.
  • safety_budget_tokens: Current balance of safety switching tokens.
  • room_pid_demand: Room temperature PID demand.
  • floor_pid_demand: Floor limiter PID demand.
  • relay_toggle_count: Total relay operations.
  • max_floor_temp: Configured absolute limit.
  • max_floor_temp_diff: Configured differential limit.

Use Cases

Engineered Wood Floors

  • Protects against warping, delamination, and shrinkage.
  • Maintains surface temperature below manufacturer's specified limit (typically 27-28°C).

Vinyl and LVT

  • Prevents softening or discoloration from excessive heat.

Comfort Applications

  • Prevents uncomfortable hot floors in cold rooms.
  • Gradual warm-up prevents thermal shock to flooring materials.
  • Maintains ASHRAE 55 / ISO 7730 comfort standards.

References

Design based on technical analysis of electric radiant floor heating control, emphasizing:

  • Relay cycle-life preservation (NEMA ICS 5-2017 standards).
  • Material safety constraints for temperature-sensitive flooring.
  • "Advanced Control Architectures for Electric Infrared Floor Heating Systems" technical analysis.
  • Physiological comfort metrics (ASHRAE 55, ISO 7730)
  • Control system stability and anti-windup strategies