Skip to content

About

PyUSB driver for Plustek OpticFilm scanners (Genesys ASIC).

Topics

Resources

Contributing

Stars

15 stars

Watchers

0 watching

Forks

Repository files navigation

pyopticfilm

Python driver for Plustek OpticFilm USB film scanners, built on PyUSB and reverse-engineered from USB captures and the SANE genesys backend.

The library talks directly to the scanner’s Genesys ASIC (GL842, GL843, GL845, or GL128) over USB—no vendor Windows driver is required once the device is bound for libusb access.

Supported hardware

Support is one of:

  • Hardware tested — live scan + park on physical hardware
  • Protocol validated — USB/register traces match a golden setup without hardware; motors stay locked
  • Experimental — tables and session code exist; scan/home/park/calibrate stay locked
Model USB ID ASIC Support
OpticFilm 8200i SE 07b3:1825 GL128 Hardware tested
OpticFilm 8100 (V2) 07b3:1824 GL128 Hardware tested (no IR)
OpticFilm 8300i SE 07b3:181f GL128 Hardware tested (IR capable)
OpticFilm 7600i v1 07b3:0c3b GL843 Hardware tested (notes)
OpticFilm 7600i v2 07b3:0c3b GL845 Hardware tested (IR capable; notes)
OpticFilm 8200i 07b3:130d GL845 Protocol validated (setup traces; scan locked)
OpticFilm 8100 07b3:130c GL845 Experimental
OpticFilm 7500i 07b3:0c13 GL843 Experimental
OpticFilm 7400 (v1 / v2) 07b3:0c3a GL845 / GL843 Experimental
OpticFilm 7300 07b3:0c12 GL843 Experimental
OpticFilm 7200i / 7200 07b3:0c04, 07b3:0807, 07b3:0c07 GL843 / GL842 Experimental

The GL845 OpticFilm 8100 (07b3:130c) is a different product from the GL128 8100 (V2) (07b3:1824).

Other OpticFilm models enumerate and open: you can read status, turn the lamp on/off (where implemented), and dump registers for bring-up. scan(), calibrate(), home(), and park() stay gated until a model is hardware-tested—calling them raises AsicError rather than risking carriage or lamp damage. Protocol validation does not flip that gate. See docs/scanner-validation.md.

Scanner.open() prefers a scan-ready device (8200i SE, 8100 V2, 8300i SE, 7600i v1, or 7600i v2) when several Plustek film scanners are connected.

Features

  • Color and infrared transparency scans at 150–7200 dpi (ASIC programs at ≥600 dpi; lower PPI shares the 600 dpi register set and is downsampled on the host; infrared is available only on supported hardware)
  • Infrared as a dust plane on ScanImage.ir (mode="infrared", or infrared=True with colour; 8200i SE, 8300i SE, 7600i v1, and 7600i v2 among the hardware-tested set)
  • Multi-exposure (ME) on GL128 hardware-tested models (8200i SE, 8100 V2, and 8300i SE): short + adaptive long colour passes with host SNR/IVW merge into ScanImage.rgb (multi_exposure=True), or a SilverFast-style fixed long pass (me_long_mode="fixed"); bracket planes via Scanner.last_me_debug. Not available at 7200 dpi
  • Multi-exposure on the GL845 7600i v2 at every resolution: the long pass raises the line period (up to 65000) and uses the same merge; see the 7600i v2 notes
  • Multi-Pass on GL128: repeat an already-validated exposure n_passes times (1–9) and stack the aligned repeats for an SNR gain — no new exposure/speed value is ever introduced, only repeats of the short pass (n_passes>1) or, combined with multi_exposure=True, of both the short and long ME passes (Adaptive Multi-Pass); per-slot stacking stats via Scanner.last_multi_pass_debug. Not available at 7200 dpi
  • Manual exposure overrides on GL128 (single_pass_exposure / me_short_exposure / me_long_exposure) for testing/debugging: bypass the adaptive/hardware-max clamps and write an exact REG_EXPOSURE value (24-bit register range)
  • Optional crop via normalized area (x1, y1, x2, y2 in 0–1)
  • GL128 dark/white shading calibration with on-disk cache (~/.cache/pyopticfilm/calib_v2.json)
  • GL128 ASIC shading path (AFE codes + shading blob) aligned with SilverFast capture order
  • Left–right orientation corrected in ImagePipeline.assemble() for mirror_x models
  • Pass registration (Multi-Exposure, Multi-Pass, IR→RGB) in pure NumPy; no OpenCV dependency
  • 16-bit RGB numpy output; optional TIFF export via tifffile
  • Progress and cancel hooks for long scans
  • Read the scanner's QuickScan / IntelliScan buttons on GL128 models (scanner.button_state())

Not implemented or out of scope here: iSRD infrared dust removal, SilverFast-style UI, or shipping a desktop app—applications own post-processing.

Changelog

See CHANGELOG.md for release notes. Latest release: v1.3.8 on GitHub.

Requirements

  • Python ≥ 3.11
  • numpy, pyusb
  • libusb 1.0 backend for PyUSB
    • Windows: libusb-package is installed automatically with pip install pyopticfilm and provides a bundled libusb-1.0.dll
    • Linux: system libusb-1.0 (e.g. libusb-1.0-0 on Debian/Ubuntu) and permission to access the device (udev rule or run as root—not recommended)
    • macOS: libusb via Homebrew or libusb-package

Optional: tifffile for ScanImage.save_tiff().

Installation

pip install pyopticfilm

From source:

git clone https://github.com/jboneng/pyopticfilm.git
cd pyopticfilm
uv sync --all-groups

USB access

The Plustek vendor driver must not own the device when using this library.

Windows

Use Zadig to replace the vendor driver with WinUSB (or libusbK) for the scanner’s USB interface. Step-by-step instructions, troubleshooting, and how to revert to the Plustek driver are in docs/windows-setup.md.

Linux

Install libusb and add a udev rule granting your user access to Plustek film scanners, for example:

# /etc/udev/rules.d/99-plustek-opticfilm.rules
SUBSYSTEM=="usb", ATTR{idVendor}=="07b3", MODE="0666"

Reload udev rules and replug the scanner.

Quick start

from pyopticfilm import Scanner

with Scanner.open() as scanner:
    print(scanner.model.model, scanner.device_id)
    scanner.warmup()  # init, home, lamp on
    image = scanner.scan(resolution=1800, mode="color")
    print(image.rgb.shape, image.rgb.dtype)  # H×W×3 uint16

    image.save_tiff("frame.tif")  # requires tifffile

Runnable examples: examples/scan.py (interactive scan to TIFF) and examples/buttons.py (scanner buttons).

For the 7600i v1, explicitly use 1440, 3600 or 7200 dpi for colour; IR supports 3600 or 7200 dpi. The shared scan() default of 1800 dpi is unsupported on this model. See the 7600i notes for calibration and acquisition limits.

Infrared scan (8200i SE, 8300i SE, or 7600i v2):

with Scanner.open() as scanner:
    scanner.warmup()
    ir = scanner.scan(resolution=1800, mode="infrared")

Multi-exposure (GL128 / hardware-tested models): short colour pass, then a frame-adaptive long pass. The long clamp is 14k–85k on all three hardware-tested GL128 models. Fallback 42000. Multi-exposure is not available at 7200 dpi (see Resolution limits below). The SNR/IVW-merged deliverable with film-base makeup is in rgb. Bracket planes and fusion stats are on :attr:~pyopticfilm.scanner.Scanner.last_me_debug (Scan Lab / audit tooling only — not part of the NegPy-facing ScanImage).

with Scanner.open() as scanner:
    scanner.warmup()
    image = scanner.scan(
        resolution=1800,
        mode="color",
        multi_exposure=True,
    )
    print(image.rgb.shape)  # SNR/IVW merged deliverable
    image.save_tiff("merged.tif")
    debug = scanner.last_me_debug
    if debug is not None:
        from pyopticfilm.image import save_rgb16_tiff

        save_rgb16_tiff(debug.rgb_short, "short.tif", dpi=image.dpi)
        save_rgb16_tiff(debug.rgb_long, "long.tif", dpi=image.dpi)
        print(debug.exposure_short, debug.exposure_long)  # e.g. 14000, 42000…85000
        print(debug.exposure_proposed, debug.exposure_reason)

Fixed multi-exposure (GL128): me_long_mode="fixed" skips the metering and scans the long pass at the model's fixed exposure on every frame, the way SilverFast does: 42000 (3× short) on the 8200i SE and 8100 V2, 60000 (4× short) on the 8300i SE, from model.me_fixed_long_exposure. The value still goes through the normal 14k–85k long clamp. Alignment, merge, film-base makeup, IR and n_passes work exactly as in adaptive mode; debug.exposure_reason is "fixed". A manual me_long_exposure takes precedence over either mode. Without multi_exposure=True the option has no effect.

image = scanner.scan(
    resolution=1800,
    mode="color",
    multi_exposure=True,
    me_long_mode="fixed",  # default "adaptive"
)

Manual exposure overrides (GL128; debugging/testing only): send an exact REG_EXPOSURE value that bypasses adaptive selection and the hardware-max clamp above — the value is written verbatim. Two limits still apply: the 24-bit register range (1–0xFFFFFF), and — at oversample == 1 resolutions (e.g. 7200 dpi) — the AHB scan motor table's 16-bit width (1–65535); either is rejected with a clear error rather than clamped or silently corrupted. All three default to None (unchanged behavior):

image = scanner.scan(
    resolution=1800,
    mode="color",
    multi_exposure=True,
    me_short_exposure=14000,
    me_long_exposure=120000,  # above the adaptive long clamp, on purpose
)

Multi-Pass (GL128): repeat the short pass (or, with multi_exposure=True, both the short and long ME passes) n_passes times and stack the aligned repeats for an SNR gain, without introducing any new exposure or scan-speed value. n_passes=1 (default) is unchanged behavior — the same Single-Pass or Adaptive Multi-Exposure scan as today. Per-slot stacking stats (align shifts, frames merged, outlier pixels) are on Scanner.last_multi_pass_debug:

# Multi-Pass: 4 repeats of the single exposure, stacked.
image = scanner.scan(resolution=1800, mode="color", n_passes=4)

# Adaptive Multi-Pass: 4 repeats each of the short AND adaptive-long
# ME passes, each slot stacked, then fused exactly as today's 2-bracket ME.
image = scanner.scan(
    resolution=1800, mode="color", multi_exposure=True, n_passes=4
)
debug = scanner.last_multi_pass_debug
if debug is not None:
    print(debug.short.stack_stats.mean_confidence, debug.short.align_shifts)

Common scan-mode combinations. multi_exposure and n_passes are independent axes, and me_long_mode only matters with multi_exposure=True. A simplified consumer UI typically only needs these combinations, named as follows:

Name multi_exposure me_long_mode n_passes
Single-Pass False — 1
Multi-Pass False — 2–9
Adaptive Multi-Exposure True "adaptive" 1
Adaptive Multi-Pass True "adaptive" 2–9
Fixed Multi-Exposure True "fixed" 1
Fixed Multi-Pass True "fixed" 2–9

Resolution limits. Multi-exposure and Multi-Pass are not available at every resolution: on the GL128 models they are off at 7200 dpi. Before offering them for a resolution, check the model; scan() raises ScanError otherwise. Models without the attributes don't support the mode at all.

model = scanner.model
me_dpis = getattr(model, "multi_exposure_resolutions_dpi", ())   # e.g. (3600, 2400, ...) — no 7200
stack_dpis = getattr(model, "multi_pass_resolutions_dpi", ())     # n_passes > 1
offer_me = dpi in me_dpis
offer_multi_pass = dpi in stack_dpis

The three manual exposure overrides above are lab/debug-only — Scan Lab (tools/scanlab/) is the reference implementation exposing the full, unrestricted parameter set; NegPy is the reference implementation of the simplified 4-combination surface.

Colour + IR in one call (8200i SE, 8300i SE, or 7600i v2; IR after the colour / ME passes):

image = scanner.scan(
    resolution=1800,
    mode="color",
    multi_exposure=True,
    infrared=True,
)
# image.rgb is the merged deliverable; image.ir is HxW uint16

Crop (normalized coordinates on the transparency window):

image = scanner.scan(
    resolution=2400,
    mode="color",
    area=(0.1, 0.1, 0.9, 0.9),  # x1, y1, x2, y2
)

Scanner buttons (GL128; tested on the 8200i SE and 8300i SE). Each call reads the USB interrupt endpoint once and returns the buttons pressed since the last read, so polling every few hundred milliseconds misses nothing. With no press it returns an empty set after timeout_ms; a real USB failure still raises UsbError. Other ASICs have no button_state. Poll from one thread, pause polling while a scan runs, and start scans from your normal scan path rather than from the polling thread:

from pyopticfilm.asic.buttons import Button

pressed = scanner.button_state(timeout_ms=250)  # set() or e.g. {Button.QUICK_SCAN}

examples/buttons.py is a complete polling loop.

List devices without opening:

from pyopticfilm.usb.device import find_devices

for info in find_devices():
    print(info.device_id, info.product_id, info.asic_hint, info.is_supported)

API overview

Entry Purpose
Scanner.open(device_id=None) Open preferred or specified OpticFilm
scanner.warmup(home=True, lamp=True) Boot ASIC, optional home + lamp
scanner.scan(...) Run a full scan → ScanImage
scanner.calibrate(...) Run shading; updates cache (unsupported on 7600i v1)
scanner.status() Read scanner status flags
scanner.button_state(timeout_ms=...) Poll the QuickScan / IntelliScan buttons (GL128)
scanner.home() / scanner.park() Motor positioning
scanner.lamp_on() / scanner.lamp_off() Lamp control (allowed on experimental models)
scanner.advanced Low-level register read/write (bring-up)
scanner.calibrator Direct access to calibration cache

ScanImage fields: rgb (uint16 H×W×3), dpi, device_model, optional ir. For ME scans, rgb is the SNR/IVW-merged deliverable (with film-base makeup). Bracket planes live on Scanner.last_me_debug, not on ScanImage.

Scan modes: "color", "infrared". "gray" is not implemented.

scan(..., multi_exposure=True) is for the hardware-tested GL128 models (8200i SE, 8100 V2, and 8300i SE) and the GL845 7600i v2. When ME is on, rgb is always SNR/IVW-merged (per-channel clip confidence, soft highlight roll-off from ~80–95% FS). The noise model is fitted from each scan's own short/long pair (last_me_debug.fusion_stats reports it); set both model.me_noise_alpha / me_noise_beta to fix it instead. Pass infrared=True with mode="color" for a dust/IR plane on the same ScanImage (8200i SE, 8300i SE, 7600i v1, and 7600i v2; the 8100 V2 has no IR). Inspect short/long via scanner.last_me_debug after the scan.

Audit a saved bracket (and optional SilverFast ME TIFF)::

PYTHONPATH=src python -m tools.audit_me_bracket short.tif long.tif --sf sf_merged.tif

Enable debug logging:

from pyopticfilm.logging import enable_debug_logging

enable_debug_logging()

For calibration problems, python tools/diag_calibration.py runs one forced calibration and zips a debug log, the build/model details and a USB trace (including the calibration strips) to attach to an issue.

Calibration

The 7600i v1 calibrates live inside every scan, without a cache. Standalone scanner.calibrate() is unsupported. apply_calib=False selects captured AFE/shading values for comparison; widened windows and derived 7200 dpi IR still recompute final shading gains.

The following cache guidance applies to GL128 models.

Each scan calibrates automatically: the first scan of a given resolution and crop in a session measures (about 6 s on the 8200i SE), and later scans of the same window in that session reuse it. Calibrations saved by earlier sessions are not reused, because lamp and sensor drift between sessions and every GL128 unit reports the same USB serial, so a swapped scanner cannot be told apart. Force a new calibration within a session with scanner.calibrate(force=True); scanner.scan(..., apply_calib=False) scans without shading.

The cache key includes resolution, crop geometry, and scan method (transparency vs infrared). GL128 colour shading uses ASIC-internal measurements at home; IR uses a white-only path, read moving like the colour white strip.

Experimental / protocol-validated models

Code for additional OpticFilm variants is included so enumeration, model selection, SANE-derived geometry tables, and hardwareless USB traces can be exercised without hardware. These paths are deliberately locked for motor moves and image acquisition:

  • model.scan_ready is True only for the 8200i SE, 8100 (V2), 8300i SE, 7600i v1, and 7600i v2; all other models stay False
  • Scanner._ensure_scan_ready() blocks scan, calibrate, home, and park on non-scan-ready models
  • GL128 motor moves stay disabled unless the model is scan-ready
  • Protocol-validated (currently OpticFilm 8200i setup traces) is not hardware support

If you have a non-scan-ready OpticFilm and want to help validate scanning, open an issue with your exact USB IDs (bcdDevice matters for some models) and we can work through capture-based bring-up. How traces are recorded and compared is in docs/scanner-validation.md.

Development

See CONTRIBUTING.md for model-lock policy and how to specialize GL128 siblings (8200i SE / 8100 V2 / 8300i SE) without retargeting frozen oracles.

uv sync --all-groups
uv run ruff check .
uv run pytest -q

Optional PyQt6 scan lab (git checkout only — not on PyPI). From the repo root, Run against MOCK is on by default; uncheck it to use a plugged-in scanner:

uv sync --group lab
uv run python -m tools.scanlab

Full UI walkthrough: tools/scanlab/README.md.

USBPcap / Wireshark .pcapng recordings used during reverse-engineering (8200i SE sessions, PPI ladder, bit-depth pairs, etc.) are published separately in pyopticfilm_captures. Use Scan Lab Open capture… to decode them offline.

CI runs on Python 3.11–3.13 (lint + tests; no hardware in CI).

Project layout:

  • src/pyopticfilm/usb/ — enumeration, claim, Genesys USB protocol, mock/recording transports
  • src/pyopticfilm/asic/ — per-ASIC drivers (GL128, GL845, …)
  • src/pyopticfilm/device/ — per-model register/geometry tables
  • src/pyopticfilm/scan/ — geometry, calibration, scan session pipeline
  • tests/scanners/ — golden USB traces, SANE log parser
  • tools/scanlab/ — PyQt6 bring-up lab (repo only; not in the PyPI package); see tools/scanlab/README.md

License

GPL-3.0-or-later — see LICENSE.

Acknowledgements

Register and motor tables for GL845-family models are derived from the SANE genesys backend (see NOTICE and docs/sane-opticfilm.md). The 8200i SE (GL128) protocol was reconstructed from USB traffic captures of the Windows driver and SilverFast; it is not present in SANE.

About

PyUSB driver for Plustek OpticFilm scanners (Genesys ASIC).

Topics

Resources

Contributing

Stars

15 stars

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages