Security Policy — IndustrialScanner

IndustrialScanner is a Python toolkit for passive analysis of ICS/OT traffic (Siemens S7Comm over TCP/102, DNP3 over TCP-UDP/20000) and read-only active probing of Modbus/TCP devices (port 502). It is designed for auditors, researchers, and educators working on industrial control systems security.

The project is actively maintained. Security reports are welcomed and will be triaged and patched.


Supported Versions

Version Supported Notes
main Yes Active development branch.
tags Best effort Tagged releases receive fixes via new tags.

If you need a fix backported to an older tag, please open an issue describing the version and the CVE/finding.


Reporting a Vulnerability

Please report security issues privately before any public disclosure:

  • Email: frangelrcbarrera@gmail.com
  • Subject prefix: [SECURITY] IndustrialScanner — <short summary>

Include in the report:

  1. Affected file(s) and line numbers (e.g., s7_comm_analyzer/parsers.py:42).
  2. A minimal reproduction (PoC) or PCAP snippet if applicable.
  3. Impact assessment and the affected protocol(s): Modbus, S7Comm, DNP3.
  4. Your suggested mitigation, if any.
  5. Whether you intend to publish the finding, and your preferred timeline.

Do not open public GitHub issues for security reports.


Response Timeline

Step Target
Acknowledgement of receipt ≤ 5 business days
Initial triage & severity rating ≤ 10 business days
Coordinated disclosure discussion ≤ 30 calendar days
Public advisory (if accepted) Mutually agreed date

The maintainer operates this project on a personal, part-time basis. The above targets are best-effort; researchers will be kept informed if delays occur.


Scope

In scope

  • The Python source tree under modbus_scanner/, s7_comm_analyzer/, dnp3_monitor/, and ics_scanner/.
  • The Jinja2 HTML templates under reports/templates/.
  • Parsing of untrusted PCAP/PCAPNG files via scapy.rdpcap.
  • HTML/JSON report generation from PCAP-derived or Modbus-derived data.
  • The CLI entry points declared in pyproject.toml.
  • The CI/CD workflows under .github/workflows/.
  • The Dockerfile and the published Docker image on GHCR.

Out of scope

  • The committed sample PCAPs under pcaps/ (public ICS training captures, anonymized; not part of the tool's runtime).
  • ModbusPal.jar, an unrelated third-party Modbus emulator bundled for convenience — report issues to its upstream project.
  • Vulnerabilities in dependencies (pymodbus, scapy, Jinja2, pydantic) — please report them to their respective maintainers via their CVE/CSAF channels.
  • Self-XSS requiring the attacker to already control the auditor's machine.

Safe Harbor

Good-faith security research on systems you own or are explicitly authorized to test is welcomed. The maintainer will not pursue civil or criminal action against researchers who:

  • Respect the in-scope/out-of-scope boundaries above.
  • Avoid disruption to live ICS/OT environments, including production PLCs, RTUs, HMIs, or SCADA hosts.
  • Do not access, exfiltrate, or destroy data that does not belong to them.
  • Provide reasonable time for acknowledgement before public disclosure.
  • Refrain from leveraging findings for extortion, ransom, or competitive gain.

Researchers who wish to validate findings against ICS protocols are strongly encouraged to use isolated lab setups such as ModbusPal, snap7, OpenPLC, or the sample PCAPs bundled with this repository.


Legal Framework

This policy is informed by widely recognized international instruments and national computer-misuse statutes. Researchers are responsible for understanding and complying with the laws of their jurisdiction.

  • Council of Europe Convention on Cybercrime (Budapest Convention, 2001) — Articles 2, 3, and 5 on illegal access, system interference, and the interference with data; Article 15 on safeguards for legitimate research.
  • United States — Computer Fraud and Abuse Act (18 U.S.C. § 1030), particularly the research and good-faith limitations recognized in recent DOJ guidelines.
  • European Union — Directive 2013/40/EU on attacks against information systems.

Nothing in this policy overrides statutory obligations; it only expresses the maintainer's intent not to refer for prosecution reports that comply with this Safe Harbor.


Security Features

IndustrialScanner implements the following security features:

Read-only by design

  • The Modbus scanner issues only function codes 0x01 Read Coils, 0x02 Read Discrete Inputs, 0x03 Read Holding Registers, 0x04 Read Input Registers. Write/control codes (0x05, 0x06, 0x0F, 0x10, etc.) are never issued.
  • S7Comm and DNP3 analyzers operate on captured PCAP files only — they send no traffic to the network.

Target safety policy

  • The CLI enforces a target safety policy: public IPs are refused by default. Pass --allow-public only after explicit written authorization from the asset owner.
  • CIDR scans are limited to /24 (256 hosts) by default.
  • Path traversal is blocked for user-supplied output filenames via ics_scanner.security.safe_join_path.

HTML/JSON output safety

  • All HTML reports use Jinja2 with autoescape=True or markupsafe.escape() on every untrusted field. This prevents stored XSS from malicious PCAPs.
  • Index builders (build_*.py) use html.escape() on every untrusted field.
  • A regression test (tests/test_xss_regression.py) verifies that <script> tags in PCAP-derived fields are escaped.

Strict protocol parsing

  • S7Comm parser uses binary decoding per the Siemens spec (TPKT/COTP unwrapping + S7 header + parameter block) with no string-based guessing.
  • DNP3 parser uses binary decoding per IEEE 1815-2012 (link layer + transport + application layer) with no pattern matching on payload bytes.
  • Property-based fuzz testing with Hypothesis verifies that the parsers never crash on arbitrary input.

CI/CD security

  • Bandit static analysis runs on every push and PR (0 HIGH findings accepted; LOW findings are reviewed).
  • pip-audit scans dependencies for known CVEs on every push and daily.
  • Semgrep runs OWASP Top 10 + Python rulesets.
  • CodeQL semantic analysis runs on every push.

No telemetry, no outbound calls

IndustrialScanner runs entirely offline. It does not:

  • Phone home
  • Send usage statistics
  • Download updates
  • Connect to any external service

All processing is local. The only network connections are the ones you initiate via the Modbus scanner.


Known Security Considerations

  • S7Comm-Plus (firmware ≥ V3.0 on S7-1200/1500) uses encrypted X3.1324 framing and is not supported. The analyzer returns NonS7Payload for these frames.
  • DNP3 Secure Authentication v5 (SA v5) is detected (function 0x1D) but the challenge-response is not validated. Whether SA v5 or another compensating control is required depends on the applicable deployment profile, asset-owner requirements, risk assessment, and target security level; IEC 62443 does not impose a universal protocol-version mandate. (Roadmap: Q2 2026.)
  • Modbus/TCP TLS (RFC 9441) is not yet implemented. Modbus traffic is sent in plaintext. (Roadmap: Q2 2026.)
  • Sample PCAPs in pcaps/ have been anonymized (public IPs replaced with synthetic 10.x.x.x addresses), but may still contain MAC addresses from lab equipment. Treat them as public artifacts.

Contact

For non-security questions, please open a regular GitHub issue.


This policy is versioned with the repository.

There aren't any published security advisories