23 changes: 23 additions & 0 deletions AGENTS.md
Original file line number Diff line number Diff line change
Expand Up @@ -182,6 +182,29 @@ PODIO relations are stored as `(collectionID, index)`. If an output collection r

CI runs `src/scripts/verify_for_dangling_references.py` on `eicrecon-gun` and `eicrecon-dis` outputs. Currently-known offenders are listed in its `KNOWN_ISSUES` set; remove entries as they are fixed.

## Unit System Policy

EICrecon mixes three unit systems. They are **not interchangeable**: `edm4eic::unit` and `Acts::UnitConstants` are millimeter/GeV/nanosecond-based (mm = GeV = ns = 1, matching EDM4hep's native convention), while `dd4hep` is centimeter/MeV-based (`dd4hep::mm` = 0.1, `dd4hep::MeV` = 1). Using the wrong system often still gives numerically correct results by accident, so intent must be made explicit.
Comment thread
veprbl marked this conversation as resolved.
Outdated

**Rules:**

1. **EDM4hep/EDM4eic object fields → `edm4eic::unit`.** Any literal, cut, or comparison involving a field read from (or written to) an `edm4hep`/`edm4eic` object (positions, momenta, energies, times, shape parameters, vertices, config parameters compared against them) MUST use `edm4eic::unit::{mm,cm,um,ns,GeV,MeV,keV,eV,...}` — unless that specific field is documented to carry exceptional units, in which case add a comment.

2. **Geometry values → `dd4hep`.** Values obtained from the detector geometry (`dd4hep::Position`, `detector()->constant<double>(...)`, cell dimensions, surface bounds) are in dd4hep native units. Use `dd4hep::` to interpret them, and convert to EDM units with the canonical idiom `value * edm4eic::unit::mm / dd4hep::mm` (or the inverse `field / edm4eic::unit::mm * dd4hep::mm`).

3. **Acts EDM / configuration → `Acts::UnitConstants`.** Values passed to or read from Acts (bound track parameters, seeding config, covariances, surface tolerances) MUST use `Acts::UnitConstants::`. Convert EDM fields at the boundary, e.g. `getQOverP() / Acts::UnitConstants::GeV`, and geometry→Acts as `x / dd4hep::mm * Acts::UnitConstants::mm`.

**Anti-patterns to flag in review** — applying `dd4hep::` units to an EDM object field, e.g.:

```cpp
if (std::abs(v.x) * dd4hep::mm > m_cfg.maxVertexX) ... // v = MCParticle::getVertex() (EDM, mm)
if (pmag * dd4hep::GeV < m_cfg.minMomentum) ... // pmag from getMomentum() (EDM, GeV)
xn.SetXYZ(rn.x * dd4hep::mm, ...); // rn = Cluster::getPosition() (EDM, mm)
if (P < 1 * dd4hep::MeV) ... // P from EDM momentum
```

These should use `edm4eic::unit::mm` / `edm4eic::unit::GeV` / `edm4eic::unit::MeV` instead. Correct reference: `PrimaryVertices.cc` (`v.x / edm4eic::unit::mm`) and `SimCalorimeterHitProcessor.cc` (`constant<double>(...) * edm4eic::unit::mm / dd4hep::mm`).
Comment thread
veprbl marked this conversation as resolved.

## Timing Expectations and Critical Warnings

**NEVER CANCEL these operations - they are expected to take significant time:**
Expand Down
Loading