Watches a Rockwell L5X PLC project file and raises a SIEM-ready alert the moment someone changes the control logic without approval — a flipped safety interlock, a raised pressure setpoint, an inhibited task — while staying quiet through the file's own normal churn (export timestamps, live counters, edits to comments). Every alert says, in an engineer's terms, what changed and maps it to the matching MITRE ATT&CK for ICS technique.
[!] CRITICAL WaterPlant.L5X: 1 unapproved change(s); most serious:
contact on Temp_High inverted (XIC -> XIO) [T0889 Modify Program]
I built this single-handedly to explore one OT-specific detection gap ahead of the Adani Cyber Sanjeevni Hackathon 2026 (Track 2). It is a working proof-of-concept of the detection idea, not a production ICS product.
The idea then grew, with teammates, into a much larger field demo — positromen/Adani-Project-OT (a.k.a. LogicWard / Vigilo). That team repo is the real hackathon submission: a two-machine attacker/defender setup running against live hardware (Raspberry Pi + Modbus), a full SOC dashboard, role-based access control, and two plant sites (a thermal plant and the GRFICS chemical reactor). Credit for that version goes to the whole team — Siddhesh Sakle (@positromen), myself (@JampaniKomal), and teammates (@akshitag001, and others).
This repo stays what it always was: the original single-author proof the drift-detection idea started from. It is deliberately narrow — one file, one clean defensive pipeline, no attack tooling — so the detection logic is easy to read and test. If you want the live, multi-site, team-scale demo, go to the repo linked above.
In an OT environment, a silent unauthorized edit to PLC logic can cause real physical damage: flip a cooling-fan interlock from "run when hot" to "run when cool", quietly raise a pressure threshold past the point where the relief valve can save the vessel, or inhibit the task that runs the safety logic at all.
Ordinary IT File Integrity Monitors are the wrong tool for this:
- They either miss it — a hash of the whole file tells you that it changed, never what, so an operator can't tell a real attack from a routine re-export.
- Or they drown you in false positives — PLC project files carry a lot of genuinely volatile data (export dates, software revisions, live timer accumulators, scan counters), and a naive monitor alerts on every one.
OT-Guard parses the L5X, separates the logic (rungs, setpoints, task configuration) from the noise (volatile metadata and runtime values it is told to ignore), and alerts only on genuine logic changes.
The v1 of this repo looked plausible but was unsound in ways that matter for a security tool. v2 is a ground-up rewrite that fixes each one:
| v1 behaviour | Why it was wrong | v2 |
|---|---|---|
| Re-synced / adopted the current file as the new baseline after an alert | An attacker just had to wait one cycle and their tampered logic became the trusted state | The baseline only changes through otguard approve, which records who approved it and why, and signs the result |
| Overwrote the monitored file from the baseline at start-up | Destroyed the evidence of any tampering done while the engine was stopped | The engine never writes a watched file; at start-up it reports drift instead of erasing it |
| Watched the file in place | Missed atomic saves (write-temp-then-rename), the way most editors actually save | Reacts to in-place writes, atomic renames, deletion and re-creation, plus a periodic rescan for events the OS never delivers |
Tagged every change T0836 labelled "Modify Control Logic" |
That label is the deprecated T0833; a logic edit is really T0889 Modify Program | Each change gets the technique that actually fits (see the mapping below), from ATT&CK for ICS v19.2 |
| Stripped volatile text only, not attributes; a live counter stored as an attribute would false-positive | The gap defeated the whole "ignore the noise" premise for real files | Normalization works on a declared allow-list of volatile attributes and tag members, flattened from the decorated data |
| Hard-coded HMAC secret; stored-XSS in the dashboard | Anyone reading the public repo could forge signatures; attacker-controlled diff text ran in the SOC's browser | Fails closed with no built-in key; the dashboard escapes every attacker-controlled string |
otguard/
l5x.py Parse an L5X into a normalized Project: rungs, tags, setpoints,
tasks, programs. Strip volatile attributes + tag members and
documentation, then fingerprint = sha256(structure c14n + values).
Refuses DOCTYPE / non-L5X input.
ladder.py Tokenize ladder text (XIC/XIO/OTE/AFI/GRT/TON...) and explain a
rung change in words ("contact on Temp_High inverted (XIC -> XIO)").
diff.py Semantic diff of two Projects -> a list of Changes, each with a
location, a plain summary, a severity, and an ATT&CK technique.
baseline.py `approve` copies the file and writes a signed manifest
(file hash, fingerprint, policy hash, approved_by, reason, HMAC).
ledger.py Append-only JSONL alert log, hash-chained and HMAC'd per line.
monitor.py The engine: verify baselines, check every file at start-up, then
watch (watchdog) + periodic rescan. Writes ECS-shaped events.
config.py otguard.toml: what to watch, what counts as volatile. The HMAC
key comes from $OT_GUARD_SECRET_KEY only — never the file.
simulate.py Demo attack scenarios + the sample WaterPlant project.
dashboard.py Pure helpers (file status, change rows, escaped diff HTML).
ui/app.py Read-only Streamlit dashboard over the ledger.
The fingerprint is the heart of it: two L5X files that differ only in volatile noise produce the same fingerprint, so a re-export is silent; any real logic change produces a different one, and the diff explains it.
| Change | Technique | Tactic |
|---|---|---|
| Rung / Structured-Text logic edited, added or removed; program or routine added/removed/disabled | T0889 Modify Program | Persistence (TA0110) |
Setpoint / parameter value changed; a Constant flag or external-access widened |
T0836 Modify Parameter | Impair Process Control (TA0106) |
| Task inhibited or its scheduling changed | T0821 Modify Controller Tasking | Execution (TA0104) |
| Alarm limit changed | T0838 Modify Alarm Settings | Inhibit Response Function (TA0107) |
The deprecated T0833 (Modify Control Logic) is deliberately absent; a test asserts it never reappears in the bundled data.
No local Python needed — the demo runs entirely in containers.
docker compose up --build # engine seeds + signs a demo baseline, then watches; dashboard on 127.0.0.1:8501Then, in another terminal, play attacker and watch the engine and dashboard react:
docker compose run --rm attacker # invert a safety contact
docker compose run --rm attacker demo attack list # list every scenario
docker compose run --rm attacker demo attack raise-setpointOpen http://127.0.0.1:8501 for the read-only dashboard, then
docker compose --profile tools down -v to stop and remove everything.
The compose file sets a public demo OT_GUARD_SECRET_KEY on purpose. It is what
signs the baselines and the ledger, so a real deployment supplies its own secret
(a secrets manager, or an uncommitted .env) and never reuses this one.
Installed as otguard (pip install . or .[dashboard] for the UI):
otguard demo init ./demo --approve # make a sandbox with a signed baseline
otguard --config ./demo/otguard.toml check # one-shot check; exit 1 on drift, --json for detail
otguard --config ./demo/otguard.toml watch # run the engine
otguard --config ./demo/otguard.toml approve --by "J. Komal" --reason "WO-7 accepted change"
otguard --config ./demo/otguard.toml verify-ledger
otguard diff approved.L5X current.L5X # explain the difference between any two filesotguard demo attack <scenario> applies one of these to the watched file (use
--atomic to save via a temporary file and rename, like a real editor):
| Scenario | What it does to the plant | Detected as | Severity |
|---|---|---|---|
invert-contact |
Cooling fan now runs only when the motor is not hot (XIC→XIO) | T0889 Modify Program | CRITICAL |
disable-interlock |
AFI inserted on the pressure interlock rung — the relief valve can never open | T0889 Modify Program | CRITICAL |
remove-interlock |
The pressure-interlock rung is deleted outright | T0889 Modify Program | CRITICAL |
raise-setpoint |
High_Pressure_SP 1000→5000 kPa — the relief valve opens far too late |
T0836 Modify Parameter | CRITICAL |
inhibit-task |
MainTask inhibited — none of the logic runs at all |
T0821 Modify Controller Tasking | CRITICAL |
shorten-timer |
Valve_Delay preset 5000→500 ms — the pump may restart almost immediately |
T0836 Modify Parameter | HIGH |
unlock-setpoint |
High_Pressure_SP loses its Constant flag — now writable from outside the controller |
T0836 Modify Parameter | HIGH |
benign-export |
A later re-export: new timestamps, live values, a timer accumulator, a new comment — no logic change | (nothing — stays quiet) | — |
benign-export is the important one: it proves the normalizer separates noise
from logic, so the tool doesn't cry wolf on routine engineering activity.
pip install .[dev]
pytest # 67 tests
ruff check .The suite drives the real parser, diff, baseline signing and ledger against real
L5X bytes, runs the monitor against a real watchdog observer (in-place edit,
atomic save, deletion, and a rescan path with a deaf observer), exercises every
attack scenario end to end, and renders the Streamlit dashboard via AppTest —
including a stored-XSS attempt through attacker-controlled diff text.
This is a prototype of one detection idea, not a complete ICS security product:
- L5X files only. It diffs Rockwell L5X exports. Siemens, CODESYS and other vendors use entirely different formats and aren't parsed.
- File-level, not live controller memory. It watches a project file on disk. It does not read the running controller, so logic changed live and never exported is out of scope — this complements, not replaces, controller-level monitoring.
- You must tell it which live values are volatile. The defaults cover timer
and counter runtime members; any other genuinely live tag (a process variable
written every scan) has to be listed under
[normalize]inotguard.toml, or it will be treated as a security-relevant value and flagged on every change. - Ledger tail truncation.
verify-ledgerdetects any edit to or reordering of existing lines via the hash chain and per-line MACs, but an attacker who can delete the most recent lines wholesale leaves a shorter-but-valid chain; catching that needs an external high-water mark (ship each line to a remote collector, which is the intended SIEM integration). - No authentication on the dashboard. It is read-only and escapes all alert text, but it has no login — fine for a local demo, not for a SOC-facing deployment as-is.
MIT — see LICENSE.