Skip to content

GUI: transient tests, per-fixture results, passed panels that go - #6

Merged
jp-pino merged 3 commits into
masterfrom
blueye/transient-tests
Oct 15, 2026
Merged

jp-pino merged 3 commits into
masterfrom
blueye/transient-tests

Conversation

@jp-pino

@jp-pino jp-pino commented Oct 15, 2026 •

Copy link
Copy Markdown

For the battery station's new start flow (BluEye-Robotics/P2-functional-tests#244). Its first column is a test that asks which slot to start next. When all four slots are running, that column should go, so the station shows at most four columns.

Changes

  • Transient tests. A test started with htf.Test(..., transient=True) (it ends up in the record's metadata) has its panel removed as soon as it completes. TestState.transient comes from test_record.metadata.transient.

  • Each fixture keeps its result. A new test now replaces only the completed tests of its own name. Before, any new test cleared every completed panel. The battery station restarts its first column whenever a slot frees up, and under the old rule a slot's PASS/FAIL would have vanished at that moment. Now a slot's result stays until that slot starts again. A station with a single test name (every other station) behaves exactly as before.

  • Passed panels can go after a delay. StationServer(..., hide_passed_after_s=120) passes the delay to the GUI in its config (ConfigService.hidePassedAfterMs). With it set, a passed test's panel is removed that long after it completes. A test that failed, errored or was aborted keeps its panel until a test of its name starts again. When it isn't set, nothing changes.

  • Transient tests stay out of History. A transient test's final record isn't added there; otherwise every one showed up as an UNKNOWN_DUT pass.

Testing

  • Two new cases in station.service.spec.ts:
    • a transient test is dropped when it completes while a slot keeps running;
    • a completed "Slot 1" survives "Slot 2" starting and is replaced when "Slot 1" starts again.
  • More cases in station.service.spec.ts:
    • a pass goes at 120 s while a FAIL next to it stays;
    • without the setting, a pass stays;
    • a transient test's final record doesn't reach History.
  • ng test in headless Chrome: 43 of 43 pass.
  • test/output/servers/station_server_test.py: the server renders hide_passed_after_s into its page, as null when it's not set. 6 of 6 pass.
  • Checked live with the battery station on the bms_tools simulator (BluEye-Robotics/P2-functional-tests#244).
  • dist/ rebuilt with Node 24; only the main bundle changes.

🤖 Generated with Claude Code

A test started with `htf.Test(..., transient=True)` (record metadata)
only serves the station while it runs, such as one that asks which
fixture to start next: its panel goes as soon as it completes.

A new test now replaces only the completed tests of its own name, so
with several fixtures on one station each keeps its result in view
until it starts again. A station with one test name behaves as before.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
@coveralls

coveralls commented Oct 15, 2026 •

Copy link
Copy Markdown

Coverage Report for CI Build 38723482313

Coverage increased (+1.3%) to 67.593%

Details

  • Coverage increased (+1.3%) from the base build.
  • Patch coverage: 1 of 1 lines across 1 file are fully covered (100%).
  • No coverage regressions found.

Uncovered Changes

No uncovered changes found.

Coverage Regressions

No coverage regressions found.


Coverage Stats

Coverage Status
Relevant Lines: 7739
Covered Lines: 5231
Line Coverage: 67.59%
Coverage Strength: 3.38 hits per line

💛 - Coveralls

jp-pino and others added 2 commits October 15, 2026 11:26
A transient test tested nothing; its final record was listed in the
history as an UNKNOWN_DUT pass each time it ended.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
`StationServer(..., hide_passed_after_s=120)` passes the delay to the
frontend in its config. With several fixtures on one station, a passed
test's panel then goes that long after it completes, while one that
failed, errored or was aborted stays until a test of its name starts
again: fixtures that run for hours mostly finish with nobody watching,
and a failure must still be on screen when someone comes back. Unset,
nothing changes.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
@jp-pino jp-pino changed the title GUI: transient tests, and each fixture keeps its result GUI: transient tests, per-fixture results, passed panels that go Oct 15, 2026
@jp-pino
jp-pino merged commit 17d97d9 into master Oct 15, 2026
14 checks passed
@jp-pino jp-pino mentioned this pull request Oct 15, 2026
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment