L5X Lint

Static analysis for Rockwell Studio 5000 .L5X exports. L5X Lint reads the export, checks it against a fixed checklist of 49 programming rules, and reports the findings. It only reports. It never modifies your project. All corrections are made by the engineer in Studio 5000.

Everything runs locally: no cloud, no internet access (no web fonts or CDNs), suitable for an air-gapped OT network.

Quick start

pip install -r requirements.txt     # flask, openpyxl, reportlab
python app.py                       # opens http://127.0.0.1:5002

Options: --port N, --no-browser. Drop one .L5X (single report) or several (batch summary) onto the page.

Rule codes and severity

Every rule has a code whose prefix is its severity:

Prefix Severity Meaning
CRT Critical Do not download to a controller until resolved
ERR Error Defect or fault risk
WAR Warning Standards violation or maintainability risk
INF Info Documentation and housekeeping

Severity is fixed by the code. In Settings → Rule Checklist each rule can only be switched on or off; a configurable severity would make the code lie.

Rule checklist

Code Rule Description
CRT001 Forces Present The export contains forced I/O or tag values. Forces must be removed before the project is released.
CRT002 AFI In Rung An AFI (Always False) instruction disables the whole rung. Remove it or replace it with proper logic.
ERR001 Duplicate OTE The same tag or bit is driven by more than one OTE. Only the last one in scan order takes effect.
ERR002 Multiple OTL A tag is latched (OTL) from more than one place, which makes its state hard to trace.
ERR003 Multiple OTU A tag is unlatched (OTU) from more than one place, which makes its state hard to trace.
ERR004 Write to MSG Status Bit Logic writes a status bit (.EN, .DN, .ER …) of a MESSAGE tag, which the controller manages. The tag type is resolved through UDTs and arrays.
ERR005 Write to Timer/Counter Bit Logic writes a .DN, .EN, .TT (or counter) bit of a TIMER or COUNTER, which the controller manages. The tag type is resolved through UDTs and arrays.
ERR006 MSG Not Gated A MSG instruction runs without ONS or timer gating, so it is re-triggered every scan.
ERR007 Controller Fault Handler No Controller Fault Handler program is configured, or it names a program that doesn't exist.
ERR008 Program Fault Routine A program has no Fault Routine assigned, or names a routine that doesn't exist.
ERR009 AOI Uses Controller Tag AOI logic references a controller-scoped tag directly, which breaks AOI encapsulation.
ERR010 Duplicate Instruction In Rung The same instruction with the same operand appears twice in one series chain, or two parallel branch legs are identical. Shared instructions in legs with other conditions are valid OR logic and not reported.
ERR011 Unchecked Array Index An array is indexed by a tag (Arr[Idx]) without a LIM/LES/GRT range check on the index placed before it on the same path. An out-of-range index causes a major fault.
ERR012 Unguarded Division A DIV, MOD or '/' in CPT divides by a tag that is not compared against zero before it on the same path.
ERR013 Backward Jump A JMP jumps to a LBL at or above itself, creating a loop inside the scan (watchdog risk).
ERR014 Timer/Counter Reused One TIMER or COUNTER tag is used by more than one timer/counter instruction. (One CTU plus one CTD on the same counter is allowed.)
ERR015 One-Shot Storage Reused An ONS/OSR/OSF storage bit is shared by several one-shots, or is also written by other logic, so edges get missed.
ERR016 No Reset For RTO/Counter An RTO or counter accumulates but is never reset (no RES and no write to .ACC). For arrays, a reset of any element via an index counts.
ERR017 Discontinued Module An I/O module catalog is Discontinued according to the lifecycle dataset. Spares may be unobtainable.
WAR001 Safety Map Naming A standard tag mapped to safety tag SFTY_X must be named STD_X.
WAR002 Produced/Consumed Naming A consumed tag must use the same name as the produced tag it maps to, with PRO replaced by CON.
WAR003 Task Name Missing Period A periodic task's name must state its period (e.g. Task_10MS for a 10 ms task).
WAR004 Uncalled Routine A routine is not called by any JSR in its program.
WAR005 Unscheduled Program A program is not scheduled in any task.
WAR006 Empty Rung A rung contains no instructions.
WAR007 Empty Branch A branch leg contains no instructions, which acts as an always-true bypass.
WAR008 Timer Preset Not Set A timer used in logic has preset 0 in its tag data and logic never sets .PRE. Timer arrays are checked per element.
WAR009 Watchdog Margin Too Small A task's watchdog is less than 1.5 × its period, so one slow scan can fault the controller.
WAR010 UDT Padding Waste Reordering this UDT's members would save at least 4 bytes of alignment padding.
WAR011 UDT Member Order UDT members are not grouped by data type, or not in alphabetical order (natural order: Valve2 before Valve10).
WAR013 MSGs Not Staggered Two or more MSGs share the same trigger condition and fire together.
WAR014 JSR Nesting Too Deep A JSR call chain is nested deeper than the limit.
WAR015 MOV REAL To Integer A MOV converts a REAL into an integer type. MOV rounds silently (.5 to even) and can overflow. Use TRN or explicit, commented rounding.
WAR016 INT/SINT Instead Of DINT A tag uses INT or SINT. Logix is 32-bit native, so DINT is faster and avoids conversion.
WAR017 Physical I/O Point Not Mapped No direct mapping logic references a field-data point of a physical I/O module (e.g. Local:4:I.Data.3, Ch0Data). Points covered by an alias are reported by WAR022 instead. Status and fault members are excluded.
WAR018 Physical I/O Point Without Comment An I/O point referenced directly in logic has no comment on the module I/O tag. One finding per point.
WAR019 Used Tag Marked Spare A tag, array element or bit is used in logic but its description or comment contains the word 'spare' or 'unused'.
WAR020 Unused UDT/AOI Definition A UDT or AOI definition is never used by any tag, member, parameter or rung.
WAR021 End-of-Life Module An I/O module catalog has reached End of Life according to the lifecycle dataset. Plan migration.
WAR022 Alias Used For Physical I/O A tag is an alias of a physical I/O tag or point. The standard is direct mapping logic; the message says whether the alias is used in logic (replace) or not (delete).
INF001 Unused Tag A tag is declared but never read or written.
INF002 Loose BOOL Tags Standalone BOOL tags are used. Pack them into a DINT, BOOL array or UDT.
INF003 Tag Without Description A used tag has no description, or a bit that logic addresses individually has no comment.
INF004 Rung Without Comment A rung has no comment.
INF005 AOI Without Description An AOI or AOI parameter has no description.
INF006 UDT Member Without Description A UDT member has no description. One finding per member.
INF007 Hard-Coded Literal A numeric literal (other than 0, 1, -1) is used in a write instruction.
INF008 Electronic Keying Not Compatible An I/O module's electronic keying is not Compatible Module (Exact Match, Disabled or other). Compatible Module allows like-for-like spares while still blocking the wrong module.
INF009 Active Mature Module An I/O module catalog is Active Mature. Newer alternatives exist; consider them for new designs.

WAR012 (Write-Type MSG) is retired: the code is reserved and not reused, so WAR013 onward keep their numbers.

How rung structure is read. Rungs are parsed into series chains and parallel branches. ERR010 compares within one chain and across identical legs; ERR011/ERR012 accept a guard only if it sits in series before the instruction on the same path (a check in a sibling leg does not count).

Physical I/O standard: direct mapping, no aliases. Each field-data point is reported under exactly one rule: WAR017 when nothing maps it, WAR022 when an alias covers it (message says whether to replace or delete the alias). Fixing a WAR022 by deleting the alias moves an unmapped point to WAR017 — the next piece of work. WAR018 counts only comments on the module I/O tag itself.

Heuristic rules. WAR017 derives digital point counts from the catalog number (1756-IB16 → 16 points); analog channels come from the module tag data. ST/FBD/SFC routines are not rule-checked, but tag and routine references inside them count as usage (INF001, WAR004, WAR017). A clean result on these means "no evidence of a problem", not proof.

Coverage notes. FBD, SFC and ST routines, source/license-protected routines and encoded AOIs cannot be analysed; the banner states how many the file contains. If an export lacks the data a rule needs (e.g. no fault-handler attribute for ERR007), the banner and both reports say "Not verified" for that rule instead of passing silently.

Web report

  • Sidebar tree: Task → Program and AOIs, with finding counts per node. Click to scope; click again to clear.
  • By rule / By location grouping. Rule groups show the code; hovering any code shows severity, rule name and description.
  • Side panel: Expand / Collapse all task sections, click a section to collapse it, or ◀ Hide the pane entirely (▶ rail brings it back).
  • Filters: severity chips (CRT/ERR/WAR/INF), text search (matches code, rule, tag, location, message), show suppressed.
  • Views: Findings, Hardware (I/O modules + lifecycle status).
  • ⟲ New file in the toolbar closes the report and returns to upload; an ↑ button bottom-right returns to the top after scrolling.
  • One row per item: I/O points, UDT members, timer elements and bits are reported individually, so group counts are item counts.
  • Export: ⬇ Excel or ⬇ PDF of exactly what is on screen — severity chips, search text and sidebar scope. The report states those filters and lists any rules disabled in Settings; the Checklist sheet shows enabled rules only.
  • Settings round trip: Save Settings (or ← Back to report) returns to the report, re-analysed with the new rule selection — no re-upload needed (within the 1-hour session). A browser refresh does the same.
  • Progress: a centred ring shows the % and current analysis phase for uploads, reloads and batch files (indeterminate while a file transfers).

Reports

Export needs openpyxl (Excel) and reportlab (PDF). If either is missing the console warns at startup and the button is disabled with a tooltip — run pip install -r requirements.txt and restart. Any other export failure shows its actual reason; the full traceback is in the console.

Excel — sheets: Summary (counts are live formulas), Findings, Suppressed, Hardware, Checklist (findings per rule).

PDF — A4 landscape: summary, findings table (header repeats on each page), and hardware & lifecycle (when lifecycle is on). Footer on every page: page x of y, generated by (computer \ user), generated on (DD/MM/YYYY HH:mm:ss), template version.

Lifecycle

I/O module status comes from lifecycle.json (seed data, unverified — verify against Rockwell PCDC before procurement decisions).

On/off: Settings → Lifecycle → Lifecycle checks is the only control for ERR017/WAR021/INF009 (they are locked in the Rule Checklist). Off removes those findings and the whole hardware/lifecycle section from both reports — no Hardware sheet or page, no lifecycle wording.

Refreshing the data (e.g. with an online assistant):

  1. Export the sheet: ⬇ Lifecycle sheet in the Hardware view (catalogs in the loaded project) or ⬇ Export dataset (Excel) in Settings (all).
  2. Fill it in. The Instructions sheet has a ready-to-paste prompt; Status is a dropdown, dates are text (YYYY-MM-DD), and each row should cite a Source URL — rows without one are imported but shown as unverified. Rows left Unknown are not imported, so nothing is guessed.
  3. Settings → Lifecycle → ⤒ Import the .xlsx or .csv. A review shows every status change, new catalogs and missing sources; nothing is saved until you click Apply changes.

Command line

python l5x_cli.py analyze Line1.L5X                       # text
python l5x_cli.py analyze Line1.L5X --format json          # JSON
python l5x_cli.py analyze Line1.L5X --format sarif         # CI annotations
python l5x_cli.py analyze Line1.L5X --fail-on ERROR        # exit 1 on ERR/CRT
python l5x_cli.py batch *.L5X

Exit codes: 0 clean (below threshold), 1 findings at/above --fail-on, 2 parse or I/O error.

Configuration

evaluator_config.json (written by Settings; do not commit it):

{
  "disabled_rules": ["INF004", "WAR016"],
  "sizes": {"loose_bool_min": 1},
  "urs":   {"safety_prefix": "SFTY_", "std_prefix": "STD_"}
}

Saving from Settings merges into this file; sections the page doesn't edit are preserved.

Project layout

app.py              Flask app: upload, live analysis stream, exports, settings, lifecycle
l5x_cli.py          Command line (text / JSON / SARIF, --fail-on, batch)
analysis.py         Pipeline (load → rules → checklist → suppression) and report builder
rules.py            The rule checklist: codes, titles, descriptions, fixed severities

checks/             All rules, grouped by what they look at
  __init__.py       run_rules() — fixed execution order (= finding order in reports)
  common.py         Shared context: parsed rungs, operand type resolution, helpers
  logic.py          Rung logic (AFI, OTE/OTL/OTU, MSG, guards, jumps, timers, JSR depth…)
  tags.py           Tags (unused, descriptions, BOOL/INT, spare, presets, P/C + safety naming)
  io.py             Physical I/O (mapping, aliases, point comments, keying)
  udt.py            UDTs (padding, member order, unused, member descriptions)
  program.py        Tasks / programs / controller (forces, watchdog, scheduling, fault handlers, AOIs)

l5x_loader.py       Single XML parse → data model
udt_layout.py       Rockwell UDT memory layout (sizes, padding, optimal order)
cross_ref.py        Tag read/write cross-reference
rung_parser.py      Flat instruction list of a rung (cached)
rung_tree.py        Series/parallel branch structure of a rung (cached)
lifecycle.py        Module lifecycle dataset, lookup, sheet export/import
suppression.py      lint:disable directives
report_export.py    Excel and PDF reports
output_formats.py   JSON and SARIF
base_check.py       Finding dataclass, rule gate
severity.py         Severity counts
templates/, static/ Web UI
tests/test_rules.py Test suite

To add a rule: register its code in rules.py, write the function in the matching checks/ module, add it to the order in checks/__init__.py, and add a violating and a compliant case to the tests.

Tests

python tests/test_rules.py

Every rule has a violating and a compliant case. The suite also renders the web UI against a real report (Node.js required) and exercises the export endpoints and CLI. Test-only dependency: pypdf (reads exported PDFs).

Limitations

  • Ladder only (see coverage note above).
  • Single-rung heuristics for ERR011–ERR013 and WAR017.
  • L5X attribute names for electronic keying, module comments, safety tag maps and fault-handler programs were written from the documented schema; confirm against a real export from your Studio 5000 version.
  • The lifecycle seed dataset is unverified.